User Manual
A9000
AC Power Source
6.3.2.2 OUTPUT Subsystem
Following are tree system for OUTPUT command:
OUTPut
:MODE
Following are functions, examples and returned parameter of OUTPUT command:
OUTPut
Function :Turn on or turn off output
Example :OUTPut?
Parameter :OFF | ON
Parameter returns
OUTPut:MODE
Function :Set output mode. "FIXED" mode output fixed voltage waveform
Example :OUTPut:MODE?
Parameter :FIXED | LIST | PULSE | STEP
Parameter returns
6.3.2.3 SOURCE Subsystem
Following are tree system for SOURCE command:
[SOURce:]
CURRent
:LIMit
:DELay
:INRush
FREQuency
87
│ www.deltaww.com
set or query output status
set or query output mode
OUTPut ON
:OFF | ON
OUTPut:MODE LIST
:FIXED | LIST | PULSE | STEP
Set(query) total output current limitation Irms
Set(query) delay time to trigger over current protection
:STARt
Set(query) time to start to measure inrush current
:INTerval
Set(query) inrush current measurement time
Set(query) frequency of output voltage
Query output status
turn on output
Query output mode
set output as LIST mode