1. De-integrating the device: When removing a MRA from ELAN, the unit must be connected and
powered on when deleting the device from the configurator. Failure to have the device connected and
running when de-integrating from ELAN will result in the MRA unit failing to return to stand-alone
mode. To correct this, read and delete the MRA to ELAN while the unit is connected and powered
on.\
2. Integrating an MRA Unit that has been previously configured in stand-alone mode: A previously
configured MRA unit will cause control issues in ELAN unless it has been reset to its default
(deconfigured) state. Install MRA Software 1.4.5xx or higher in the MRA unit, then enter PIN code
1345 in the MRA Configuration Wizard to access a configuration reset button.
3. KP7 Feedback Issues: Older versions of the MRA Software have a communication device for the
KP7 that can interfere with the communication device in ELAN resulting in incorrect feedback when
saving favorites. Version 1.4.5xx and above of the MRA software correct this issue.