NIVELCO EasyTREK SCD-34 4 Series Installation And Programming Manual

NIVELCO EasyTREK SCD-34 4 Series Installation And Programming Manual

Compact ultrasonic level transmitter for free flowing solids

Advertisement

Quick Links

scd340en21p07
1 / 32

Advertisement

Table of Contents
loading

Summary of Contents for NIVELCO EasyTREK SCD-34 4 Series

  • Page 1  scd340en21p07 1 / 32...
  • Page 2  2 / 32 scd340en21p07...
  • Page 3: Table Of Contents

    C O N T E N T S   INTRODUCTION ................... 5   TECHICAL DATA .................. 6         2.1.................... 6 ENERAL DATA     2.2..................... 7 PECIAL DATA     2.3..................7 X INFORMATION  ...
  • Page 4 CERTIFICATES: Reference document number BKI ATEX,Certificate No.: BKI16ATEX0020X/1 scd3404m060bp_07 EAC, Certificate No: RU C-HU. IM43.B.01471 scd3404o0600p_02  scd340en21p07 4 / 32...
  • Page 5: Introduction

    A beam angle of 5 at –3 dB is a feature of all NIVELCO’s ultrasonic sensors designed for the level measurement of free flowing solids. This uniquely narrow beam angle ensures reliable measurement in narrow silos with uneven side walls or sometimes even in the presence of dusting.
  • Page 6: Techical Data

    The following types of applications are possible depending on the communication and what the output signal is used for: 1. 1.Using the unit as a three - or four -wire current transmitter. Normally, we use the analogue (4…20 mA) output signal of the EasyTREK. The application parameters of the device are set through HART communication at installation (right after installation or in a laboratory, prior to installation).
  • Page 7: Special Data

    2.2. Special data Type SCD–34–4 SCD–34–8 Ex SCD–33–4 SCD–33–8 Ex SCD–31–4 SCD–31–8 Ex Maximum measuring distance X 15 m (50 ft) 30 m (100 ft) 60 m (200 ft) Minimum measuring distance X 0.6 m (2 ft) 0.6 m (2 ft) 1 m (3.3 ft) Ultrasound frequency 40 kHz...
  • Page 8: Order Codes

    2.5. Order codes EasyTREK D – 3 – Range / Frequency Code Mounting Code Output / Certificates Code 1…60 m (15 kHz) 1" BSP thread 4…20 mA + HART+ Relay 0.6…30 m (30 kHz) Aiming device 4…20 mA + HART+ SSR / Ex ma ta IIIC 0.6…15 m (40 kHz) * Order codes of Ex versions end in ’Ex’...
  • Page 9: Dimensions

    2.6. Dimensions SCD–310– SCD–310– Ex SCD–330– SCD–340– SCD–330–8 Ex SCD–340–8 Ex SCD–33J– SCD–33J–8 Ex SAA–102 SCD–31J– SCD–31J–8 Ex SCD–34J– SCD–34J–8 Ex Ball-joint Housing (view from above)  scd340en21p07 9 / 32...
  • Page 10: Installation

    INSTALLATION LACEMENT To find the ideal position for the location of the EasyTREK level transmitter various considerations should be made. The transmitter should not be installed in the center of the tank/silo when the tank roof is dome shaped or conical. The ideal position for the EasyTREK is on the r = (0.3…0.5) R (in case of cylindrical tank).
  • Page 11: Wiring

    IAMETER OF THE PENING AXIMUM HICKNESS OF THE D (mm / inch) V (mm / inch) 160 / 6.3 110 / 4.3 190 / 7.5 150 / 5.9 230 / 9 200 / 7.9 300 / 11.8 280 / 11 340 / 13.4 300 / 11.8 Figure 1.
  • Page 12 Multiple SCD–300 transmitters connected to a MultiCONT process HART communication and power supply of one SCD-300 transmitter from the MultiCONT process control unit. Power is supplied from a common external source; the relays control unit. are not used. Trial and laboratory programming of the SCD–300 transmitters. ...
  • Page 13: Putting Into Operation, Adjusting, Programming

    PUTTING INTO OPERATION, ADJUSTING, PROGRAMMING 5.1. Putting into operation After switching on the correctly wired unit the transducer begins to click audibly. In about 20…50 s the ECHO LED goes on and a signal between 4…20 mA appears on the current output. When first powering the unit, it measures with the standard manufacturer’s settings (see some of the most important parameters below).
  • Page 14: Status Indication Signals In Measuring Mode

    With the aid of EView configuration software run on PC  By the NIVELCO made MultiCONT multichannel controller This instruction describes parameters and features behind them but does not deal with technical details for their selection and editing of their values. Compact Disk attached to the transmitter contains detailed information on the Eview configuration software (to install on PC) and its description.
  • Page 15: Parameters -Description And Programming

    5.4. Parameters –Description and programming 5.4.1. Measurement Configuration P00: - c b a Application/Engineering Units FACTORY DEFAULT: 001 ATTENTION! Programming of this parameter will result in loading the factory default with the corresponding engineering units. PERATING MEASUREMENT MODE Free flowing solids level measurement „...
  • Page 16 P01: - - 1 a Measurement Mode FACTORY DEFAULT: 11 Values transmitted by HART protocol, current output and the switching points of the relays will be interpreted into the engineering units of the (measured or calculated) process value corresponding to the programmed measurement mode. On the other hand, the higher the “a” of the programmed parameter value the more (measured or calculated) process values can be transmitted through HART (e.g., if P01=0 only the Distance, if P01=4 Distance, Level and Volume;...
  • Page 17 P02: - c b a Calculation units FACTORY DEFAULT: 000 EMPERATURE °C °F Volume Weight (set also P32) This table is interpreted according to P00(c), P01(a) and P02(c) and Metric Metric is irrelevant in case of percentage lb (pound) measurement (P01(a)= 2 or 4) liter gallon The value of character c has no significance at devices for solids...
  • Page 18 P05: - - - - Minimum measuring distance (Close-end blocking) FACTORY DEFAULT: automatic close end blocking (Xm as per the table) Basic feature of the ultrasound level meters is they’re not being able to measure next to the sensor surface. Within this range the measurement cannot be interpreted, thus it should be avoided that material level get into this range.
  • Page 19 P06: - - - - Far-end blocking FACTORY DEFAULT: 0 Far-end blocking is the range below the level set in parameter P06. Far-end blocking can be used to avoid disturbing effects of stirrers or heaters at the bottom of the tanks. When the unit detects echoes in this range it gives special signals.
  • Page 20: Current Value

    5.4.2. Current value P08: - - - - Fixed output current FACTORY DEFAULT: 0 With this step the output current can be set as a fix value, selected between 3.8 mA and 20.5 mA. Output current will be fixed until the value of P08 is programmed back to 0 again.
  • Page 21: Relay Output

    5.4.3. Relay output P13: - - - a Relay functions FACTORY DEFAULT: 2 ARAMETERS TO BE ELAY FUNCTIONS PROGRAMMED P14, P15 If the value selected for controlling the relay DIFFERENTIAL LEVEL Keep at least 20 mm increases over P14 : relay energizes CONTROL (0.79 inch) difference decreases below P15 : relay de- energizes...
  • Page 22: Measurement Optimalization

    5.4.4. Measurement optimalization P20: - - - a Damping FACTORY DEFAULT: 7 This parameter can be used for reduction of unwanted fluctuation of the displayed value and the output. Granules Damping time [s] particle size >2-3 mm (0.08-0.118 inch) particle size < 1-2 mm (0.04-0.08 inch) OR TEST ONLY Not recommended Not recommended...
  • Page 23 P24: - - - a Target tracking speed FACTORY DEFAULT: 0 With this parameter the evaluation can be sped up at the expense of the accuracy. Tracking speed Remark Standard For most applications Fast For fast changing level For very special cases only, as this reduces the maximum measuring range to 50% of the nominal value! The Special measuring window (P25 and P33) is inactive and the EasyTREK will respond practically instantly to any target.
  • Page 24 P28 - - - a Echo-loss handling FACTORY DEFAULT: 0 LOSS ERROR EMARK INDICATION During short periods of echo-loss, both Eview and the analogue output will hold last value. The current output holds last value for twice as long as set in P20 before going to the "Error Indication Mode" set in P12.
  • Page 25 P29 - - - - Blocking out of object FACTORY DEFAULT: 0 One object in the tank/silo disturbing measurement can be blocked out. Enter distance of the object from the transducer. Use the Echo Map (P70) to read out the precise distance of disturbing objects. P31: - - - - Sound velocity at +20 °C (+68 °F) [m/s or ft/s] FACTORY DEFAULT: metric: 343.8 m/s, US: 1128 ft/s...
  • Page 26: Volume Measurement

    ANUAL ECHO SELECTION 5.4.5. Volume measurement P40: - - ba Tank / silo shape FACTORY DEFAULT: 00 Other parameters to be Tank/silo shape Caution! Standing cylindrical tank shape: value of “b” as below bottom P40(b), P41 The value "a" defining the shape Standing cylindrical tank/silo with conical bottom P41, P43, P44 of the container must be set...
  • Page 27: Linearisation

    P41-45: - - - - Tank / silo dimensions FACTORY DEFAULT: P41 ... P45 = 0 Standing cylindrical tank/silo Standing cylindrical tank/silo Standing rectangular tank/silo with hemispherical bottom a = 0 with conical bottom a = 1, b = 0 with or without chute a = 2, b = 0 For flat bottom P43, P44 and...
  • Page 28: Informational Parameters

    P48: - - - - Number of linearization data pairs FACTORY DEFAULT: L( i ) = 0 r( i ) = 0 The data pairs defining the characteristic points must be entered into a table of three columns. The table can be filled with pre-calculated data or data measured while filling the tank.
  • Page 29: Test Parameters

    P65: - - - - Maximum temperature of the transducer [°C] P66: - - - - Minimum temperature of the transducer [°C] P70: Number of Echoes / Echo Map (separate menu item or highlighted window) Entering this parameter the level transmitter stores the actual echo map, the amplitude and the position of the echoes. The distance and amplitude of these echoes can be read-out one by one in ascending order.
  • Page 30: Error Codes

    Form) must be filled and enclosed in the parcel. Download it from our website www.nivelco.com. The device must be sent back with a declaration of decontamination. A statement must be provided in the declaration that the decontamination process was successfully completed and that the device is clean from any hazardous substances.
  • Page 31: Parameter Table

    PARAMETER TABLE Par. Page Description Value Par. Page Description Value d c b a d c b a Application/Engineering Units Echo-loss handling Measurement Mode Blocking out of object Calculation units Values displayed - Rounding Sound velocity at +20 °C (+68 °F) Maximum Measuring Distance Minimum Measuring Distance Specific gravity...
  • Page 32 Position of the selected echo Signal to Noise Ratio Checksum Blocking Distance Software code Hardware code Access lock by secret code scd340en21p07 December 2021 NIVELCO reserves the right to change anything in this manual without notice!.  32 / 32 scd340en21p07...