Asko DWCBI331.W Operating Instructions Manual page 42

Table of Contents

Advertisement

Installation
WARNING!
Danger of contact with high voltage! Remove the plug from the wall socket.
Connect the cables
Connect the external cables for automated dosage to the back of the dishwasher.
Connection of cables
1. Loosen the screw to open the panel.
2. Feed the external cables through the cable gland, and connect them together with the
dishwasher's cables.
Black cables: Connection for impulse of detergent (230 V)
Brown cables: Connection for impulse of rinse aid (230 V)
Yellow/green cable: Earth connection
3. Fasten the cables and the connection block to the inside of the panel using the adapted cable
tie.
4. Set the panel back in place.
5. Tighten the strain relief on the cable gland.
The length of the external cables must not exceed 3.0 m.
Connect the hoses
Connect the hoses supplied for automated dosage at the back of the dishwasher.
1. Connection for detergent (hose diameter 6 mm). Remove the plug and connect the hose.
2. Connection for rinse aid (hose diameter 4 mm). Remove the plug and connect the hose.