Filter Service and Replacement

Automatic Filter Cleaning System (FCS)

QUATRO has developed the Filter Cleaning System (FCS) which is an automatic filter cleaning system that continuously
maintains the main filter to facilitate maintenance. It functions by using a vibration motor to clean the filter, shaking the
accumulated debris down into the dust collection tray beneath it. The Filter Cleaning System operates in 1 of 2 automatic
modes, OffLine and OnLine Cleaning. Each mode performs cleaning cycles as described below.
One cleaning cycle is a 7-second cleaning followed by a 5-second pause and is indicated by L4 is flashing quickly.

OFFLine Filter Cleaning

If Auto-Cleaning Filter Led is OFF while operating, you are working in OFFLine cleaning mode.
The Filter Cleaning System will automatically perform one cleaning cycle after 45 minutes of accumulated operation time up
to a maximum of 2 cleanings ONLY AFTER THE UNIT HAS BEEN SHUT-OFF for a few seconds. The 45 minute frequency
is the default setting and can be changed to 15, 30, 60 minutes. See
16.
If operating more than 120 minutes at a time or in a heavy dust environment, Quatro recommends using the OnLine cleaning
mode
.

OnLine Filter Cleaning (Default Setting)

NOTE: Recommended setting for milling or any continuous dust-generating process.
If Auto-Cleaning Filter LED is flashing SLOWLY while operating, you are working in OnLine Filter cleaning mode.
This is an automatic cleaning system, specifically designed for users operating the unit for longer periods of time or for
automated process (Ex. Connected to a CAD/CAM Milling Machine). The Filter Cleaning System will automatically stop
to clean the filter once every 45 minutes of operation time. This short pause to clean the filter does not normally cause
debris accumulation in the work area. The 45 minute frequency is the default setting and can be changed to 15, 30, 60
minutes. See
"Filter Cleaning System (FCS) Setting Menu" on page

On Demand Filter Cleaning

If additional cleaning is required, an On Demand EXTRA CLEANING FEATURE is included.
To initiate, do the following:
1. Unit must be ON Or Operating By Remote Control Or In Remote/Standby.
On Demand Filter Cleaning is not accessible when the unit is OFF or in Temporary ON.
2. PRESS and HOLD POWER button until then unit beeps constantly THEN release POWER button.
(There will be a short pause, followed by a cleaning cycle)
3. Once cleaning cycle is completed, unit will then go back to previous operating mode.
Page 15
Filter Service and Replacement
"Filter Cleaning System (FCS) Setting Menu" on page
16.
© Quatro Air Technologies| MAY 2019 | All rights reserved |

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ivac compact 2.0Ivac infinity 2.0Ivac twin 2.0

Table of Contents