Normal (Manual) Operation; Variable Digital Speed Control And Autoflow - Quatro Premium iVAC Series Operation And Maintenance Manual

Turbine dust collectors
Table of Contents

Advertisement

iVAC Premium Series Operation and Maintenence Manual
Light
Status
Audible
(LED)
Alert
Filter
Flashing
Cleaning
Slowly
System
LED 4 (L4)
Flashing
Quickly
SOLID
SOLID
Remote
SOLID
Standby
LED 5 (L5)
Fading
IN-OUT
Flashing
Slowly
ALL LEDS
Flashing
Beep Every
Slowly
** If SYSTEM ON LED is SOLID, but unit NOT operating,
Replacement" on page 23 For More Motor Info & Reset Alert Instructions .

Normal (Manual) Operation

Manual operation of the unit is accomplished by using the (Red) POWER button.

Variable Digital Speed Control and AUTOFLOW

Speed control is available in all modes of operation (manual and automatic) and is adjusted with the UP and DOWN
arrows.
AUTOFLOW is an automatic system pressure compensation system. After setting the minimum speed required to
properly evacuate your equipment, the controls will automatically increase the motor speed to compensate for the
increased pressure as a result of filters getting dirty or a system blockage until maximum speed is reached. After a
filter change, system will automatically decrease the speed to the original set point. Please verify that you are achieving
adequate ventilation after a filter change. If not adjust blower speed.
Page 12
Condition
Online Cleaning Mode
Filter Being Cleaned
FCS Motor Service Life
Expired
FCS Alarm Muted
L1 Flashing Slowly
Receiving Remote Signal
Shutdown Delay
Unit Is In Standby
* Low System Pressure
Second
Description/Action
During Operation Unit Will Stop For 15 Seconds To Clean Filter And Then
See
"Filter Service and Replacement"
See
"Filter Service and Replacement"
See "Filter Service and Replacement" on page 15
Replace FCS Motor ASAP And RESET ALERT
Alarm Mute Details On Previous Page
See
"Filter Service and Replacement"
Remote Switch Closed (On) OR Receiving Remote Signal From Another
Piece Of Equipment OR Mc2 Remote Function (If Equipped)
QUATRO System Continues To Run For A Short Period To Remove All
Waiting For Remote Switch To Close (Turn On) OR To Receiving Remote
Signal From Another Piece Of Equipment OR Mc2 Remote Function (If
Abnormally Low Pressure, Unit will BEEP & Shutdown In 5 Seconds
Unit Will Continue To Shutdown Unit Until The Issue Is Addressed
-Motor(s) Not Operating Due To Service Required Or Failure
See
"Motor Service and Replacement" on page 23
Operating Due To Excess Heat.
See
"Filter Service and Replacement" on page 15
Open. Close All Access Doors
-Filters Not Or Improperly Installed. Verify Filters
Motor Not Operating Due To Service Required Or Failure, See "Motor Service and
© Quatro Air Technologies| MAY 2019 | All rights reserved |
Resume Operation
on page 15
on page 15
on page 15
Debris From Work Area
Equipped)
-Access Door(s)
Controls
-Motors Not

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ivac compact 2.0Ivac infinity 2.0Ivac twin 2.0

Table of Contents