Led Diagnostics Table R17.0 And Higher - Ivac - Quatro Premium iVAC Series Operation And Maintenance Manual

Turbine dust collectors
Table of Contents

Advertisement

iVAC Premium Series Operation and Maintenence Manual
If there are any additional alarms when MUTED, mute will disable itself until muted again, then BOTH alarms will be
muted.
Muted alarms will only be displayed while the unit is in operation. If the unit is turned off and then on during the 8 hour
mute, the balance of the 8 hour mute will continue after the unit is turned on again.

LED Diagnostics Table R17.0 And Higher - iVac

Light
Status
Audible
(LED)
Alert
System
SOLID
ON
Fading
LED 1
IN-OUT
(L1)
Flashing
Slowly
Service
SOLID
Beep Every
Motors
LED 2 (L2)
SOLID
Beep Every
SOLID
Beep Every
SOLID
Service
Flashing
Filter (s)
Slowly
LED 3
(L3)
Flashing
Beep Every
Slowly
Flashing
Beep Every
Slowly
SOLID
Beep Every
SOLID
Page 11
Condition
Unit is ON **
Temporary ON Mode
AUDIBLE ALERT MUTED
Motor(s) Will Soon Need
4 Hrs
Service
Motor(s) Service Becoming
15 Min
Urgent
Motor(s) Service
5 Min
Required
IMMEDIATELY
Motor Alarm Muted
L1 Flashing Slowly
*Filter Pressure High
*Filter Pressure Near
Hour
Critical.
Service Becoming Urgent
*Critical Pressure
Second
Filter(s) Service Life
Hour
Expired
Filter Alarm Muted
L1 Flashing Slowly
Description/Action
POWER Button Had Been Used To Temporarily Turn Unit On While In
See
Temporary ON Mode
Alarm Condition MUTED, See L2, L3 Or L4 For Specific Alarm Condition
Quick Change Brush Motor(s) WILL SOON Require Brush Replacement
Infinity Brush Motor(s) WILL SOON Require Complete Replacement
Brushless Motor Is Almost At The End Of The Predicted Service Life
RESET ALERT After Service
See "Filter Service and Replacement" on page 15
Quick Change Brush Motors ONLY: Replace Brushes ASAP And RESET
See
"Motor Service and Replacement" on page 23
Quick Change Brush Motors ONLY: Replace Brushes IMMEDIATELY And
See
"Motor Service and Replacement" on page 23
Replace Brushes OR Motor(s) ASAP And RESET ALERT
Alarm Mute Details On Previous Page
See
"Motor Service and Replacement" on page 23
Try On Demand Filter Cleaning, Prepare To Service/Replace Filters
See
"Filter Service and Replacement" on page 15
Remove & Clean Main (Round) Filter. If Alarm Continues Either The Main
(Round) Filter Or The HEPA Filter Need To Be Replaced
Continued Operation May Result In Unit Shutdown.
High Pressure Causes Excess Motor Heat & Accelerates Brush Wear.
See
"Filter Service and Replacement" on page 15
Unit Has Shutdown To Prevent Damage From Excess Pressure
Verify Blockage – Remove Blockage
Verify All Filters – Clean/Replace Filters Accordingly
See
"Filter Service and Replacement" on page 15
Replace Filter(s) ASAP And RESET ALERT
See
"Filter Service and Replacement" on page 15
Replace Filter(s) ASAP And RESET ALERT
Alarm Mute Details On Previous Page
See
"Filter Service and Replacement" on page 15