Selecting Clock Supply - Renesas Compact Emulator M34571T2-CPE User Manual

Compact emulator for 4571 group
Table of Contents

Advertisement

M34571T2-CPE User's Manual

2.9.2 Selecting Clock Supply

This product always uses the internal oscillator circuit as a clock supply to the evaluation MCU.
1. Kinds of Oscillator Boards
The M34571T2-CPE comes with an oscillator circuit board OSC-2 (6 MHz). And an oscillator circuit bare board OSC-2 is
included with this product. A clock supplied to an MCU can be changed by replacing oscillator circuit boards.
2. Replacing Oscillator Circuit Boards
Figure 2.12 shows how to replace the oscillator circuit boards.
P2
J
P1
J
XT
E
NT
I
5.0V
3.3V
4
L E D
5
L E D
M34571T2 -CPEB REV .A
Figure 2.12 Replacing oscillator circuit boards
Note on Replacing the Oscillator Circuit Board:
When removing the upper cover or replacing the oscillator circuit boards, be sure to shut OFF the power supply.
Otherwise the internal circuit may cause a break.
REJ10J0972-0100 Rev.1.00 February 10, 2006
J4
Oscillator circuit board
The oscillator circuit board of the emulator is placed as described
on the left.
Unscrew the screw securing the oscillator circuit board.
Lift off the oscillator circuit board.
Attach the oscillator circuit board for replacement to the
connector of the emulator.
Secure the new oscillator circuit board with the screw.