4
Secure cable
Prevent cable from being dislocated by using the cable clamp
and screws. Use the sealing cones to make the installation
water resistant.
5
Electrical connection
Connect all wires and firmly press down all levers as illustrated.
Then turn on the circuit breaker to continue.
TN 3-phase
PE
N
L1 L2 L3
PE
N
L1 L2 L3
6
B
TN 1-phase
PE
N
L1 L2 L3
PE
N
L1 L2 L3
IT 3-phase
PE
L1 L2 L3
PE
L1 L2 L3
IT 1-phase
PE
L1 L2
PE
L1 L2