For Custom Models Zifi240, Zibi240; Standard Installation; Product Clearances - Monogram Fresh Food Custom ZIFI240 Installation Instructions Manual

Fresh-food refrigerator bar refrigerator with icemaker
Hide thumbs Also See for Fresh Food Custom ZIFI240:
Table of Contents

Advertisement

For Models ZIFI240 and ZIBI240 with Custom Door Panels and Handles
THE INSTALLATION SPACE
Flush Installation not allowed with custom Door
Panels and Handles

Standard installation

The product must be installed so that the product front
will project forward of the adjacent cabinets by the
dimensions T or U according to the model in the chart.
This position will allow a full door swing and prevent
interference with adjacent cabinetry. The opening
between cabinets must be a minimum of dimension K.
Front edge of
CABINET
product case
Front face
T,U
In a standard installation, the product
will project forward of adjacent
cabinets. See T,U.
Product
Extended Dimension
T
ZIFI240
U
ZIBI240
31-1000642
Design Guide
for Standard Installation only
Standard
Installation
CABINET
110°
120°
2-3/4"
2-5/8"

PRODUCT CLEARANCES

The Fresh-Food Refrigerator or Bar Refrigerator with
Icemaker is factory set for a 110° door swing.
When installed in a corner:
• Allow 16" minimum clearance on the hinge side for a
full 110° door swing.
• Allow 4-1/2" min. clearance on the hinge side for the
90° door swing and to allow racks to slide out.
16" Minimum to Wall
110 Door
Swing
110
NOTE: Custom handle clearances may vary.
NOTE: Right hand models illustrated. Allow the same
clearances on the opposite side for left hand fresh food
model ZIFI240 only. Model ZIBI240 is not available with
left hand door swing.
• Test the door swing. Carefully open and close the
door. The door should not rub or catch on adjacent
cabinetry.
NOTE: When installing custom panel and handle,
use above clearances as a general guide but adjust
according to the installation.
Choose the location:
• These products may be closed in on the top and
three sides as long as the front is unobstructed for air
circulation and proper access to the door.
• Do not install these products where the temperature
will go below 55°F (13°C) or above 100°F (37°C).
• These products are not designed to be stacked one
over the other.
90 Door
B
Swing
R
F
90
4" Minimum to Wall
9

Advertisement

Table of Contents
loading

Table of Contents