Page 2
Edition Notes The onAir IP Panel 1 User Manual includes a description, safety precautions, installation, programming, operation and maintenance instructions for the onAir IP Panel 1 as of the release date of this edition. Trademarks CHAUVET, the Chauvet logo and onAir IP Panel 1 are registered trademarks or trademarks of Chauvet & Sons, LLC (d/b/a Chauvet and Chauvet Lighting) in the United States and other countries.
Table of Contents TABLE OF CONTENTS 1. Before You Begin ............... What Is Included ................... Claims ......................Text Conventions ..................Symbols ......................FCC Compliance................... RF Exposure Warning for North America, and Australia....... Safety Notes....................Personal Safety....................Mounting and Rigging ..................Power and Wiring....................
Page 4
Table of Contents Ethernet Setting ....................Universe ........................14 Start Channel......................14 IP Address ....................... 15 Ethernet to DMX ...................... 15 Control Channel Assignments and Values............ XYExtended(10)....................XYBasic(6) ......................16Ch........................15Ch2......................... 15Ch1......................... 11Ch........................10Ch........................8Ch2........................8Ch1........................6Ch........................5Ch........................4Ch........................3Ch........................1Ch........................
Before You Begin 1. Before You Begin What Is Included • onAir IP Panel 1 • Junior pin • Seetronic Powerkon IP65 power cord • Quick Reference Guide • Omega bracket with mounting hardware Claims Carefully unpack the product immediately and check the container to make sure all the parts are in the package and are in good condition.
Before You Begin Safety Notes Read all the following safety notes before working with this product. These notes contain important information about the installation, usage, and maintenance of this product. This product contains no user-serviceable parts. Any reference to servicing in this User Manual will only apply to properly trained, certified technicians.
Introduction 2. Introduction Description The onAir IP Panel 1 is an IP65 full-spectrum LED soft light with a 1x1 format for outdoor or indoor operation. Ready for any broadcast setting, the onAir IP Panel 1 features high CRI/ TLC and TM-30 scores, a smooth 16-bit dimming curve, +/- green adjustment, an emulated redshift, built-in customizable effects, and a drop-in slot for easy changing of accessories.
Introduction Product Dimensions 22 in 559 mm 19.6 in 497.8 mm 11.81 in 300 mm 13.98 in 16.18 in 355 mm 411 mm 1.1 in 28 mm 21.81 in 554 mm 17.05 in 433.1 mm 13.97 in 354.9 mm 5.74 in 146 mm Page 4 of 27 onAir IP Panel 1 User Manual Rev.
Setup 3. Setup AC Power The onAir IP Panel 1 has an auto-ranging power supply and it can work with an input voltage range of 100 to 240 VAC, 50/60 Hz. To determine the product’s power requirements (circuit breaker, power outlet, and wiring), use the current value listed on the label affixed to the product’s back panel, or refer to the product’s specifications chart.
Setup Signal Connections The onAir IP Panel 1 can receive a DMX, Art-Net™, sACN, or a wireless Lumenradio CRMX™ signal. The product has 2 Seetronic Etherkon-compatible through ports and 5-pin DMX in and out ports. If using other compatible products with this product, you can control each individually with a single controller. Control Personalities The onAir IP Panel 1 uses a 5-pin DMX data connection, Art-Net™, sACN, or wireless CRMX™...
Setup Lumenradio CRMX™ Connection In optimal conditions, the onAir IP Panel 1 can operate up to 300 m (900 ft) away from the CRMX™ transmitter, The CRMX™ receiver in the onAir IP Panel 1 must be paired with the CRMX™ transmitter for wireless operation.
The onAir IP Panel 1 comes with an omega bracket and a junior pin. Mounting clamps are sold separately. Make sure the clamps are capable of supporting the weight of this product. Use at least two mounting points per product. For the CHAUVET Professional line of mounting clamps, go to http://www.trusst.com/ products.
Operation 4. Operation Control Panel Description Button/Knob Function <MENU> Exits from the current menu or function Enables the currently displayed menu or sets the currently selected value into the <ENTER> selected function Navigates upwards through the menu list or increases the numeric value when in a <UP>...
Operation Menu Map Refer to the onAir IP Panel 1 product page on www.chauvetprofessional.com for the latest menu map. Main Menu Programming Levels Description DMX512 Protocol Artnet Sets the control protocol sACN Selects DMX address (*Highest 001–512* channel restricted to personality Address chosen) Preset...
Page 16
Operation Main Menu Programming Levels Description 600Hz 1200Hz 2000Hz Sets the Pulse Width Modulation Frequency frequency 4000Hz 6000Hz 25KHz Auto Sets the fan to auto mode Sets the fan to always on Fan Mode Sets the fan to always off Silent Sets the fan to silent Receive Off/...
Operation Home Screen The home screen of the onAir IP Panel 1 shows the current settings and status of the product. To see the home screen, press and hold <MENU> until it shows on the display. From the home screen, press <MENU>...
Operation Configuration (DMX, Art-Net™, sACN) Use control configurations to operate the product with a DMX, Art-Net™, or sACN controller. Control Mode The onAir IP Panel 1 works with wired DMX, CRMX™, Art-Net™, and sACN control signals. To select which protocol to use: 1.
Operation IP Address To set the IP address: 1. Go to the Ethernet Setting main level. 2. Select the IP Address option. 3. Select the first value of the IP address, from 2, 10, or 239. 4. Press <ENTER> to cycle through the 4 values of the IP address. 5.
Operation 16Ch Channel Function Value Percent/Setting Red 1 000 255 0–100% Fine red 1 000 255 0–100% Green 1 000 255 0–100% Fine green 1 000 255 0–100% Blue 1 000 255 0–100% Fine blue 1 000 ...
Operation 15Ch1 Channel Function Value Percent/Setting Dimmer 000 255 0–100% Fine dimmer 000 255 0–100% 000 255 0–100% Fine red 000 255 0–100% Green 000 255 0–100% Fine green 000 255 0–100% Blue 000 255 0–100% Fine blue 000 ...
Operation Configuration (Standalone) In a standalone mode, the onAir IP Panel 1 can be controlled through the display menu, the control knobs, and/or the preset buttons. CCT Control In CCT Control mode, the control knobs have the following functions: • <DIM/INTENSITY>: Increase or decrease the dimmer value, from 00.0–100%.
Operation Effect Macros The onAir IP Panel 1 features 8 effect macros which simulate lighting effects. 1. Go to the Effect Macros main level. 2. Select the effect macro, from Color Chase, Police Car, Firetruck, Fire, Clouds, Fireworks, Paparazzi, or Lightning. 3.
Operation Wireless Lumenradio CRMX™ Settings Toggle CRMX™ To enable or disable wireless CRMX™ control: 1. Go to the Wireless Setting main level. 2. Select the Receive Off/On option. 3. Select from Off (disabled) or On (enabled). Receiver Reset To reset the CRMX™ receiver: 1.
Maintenance 5. Maintenance Product Maintenance Dust build-up reduces light output performance and can cause overheating. This can lead to reduction of the light source’s life and/or mechanical wear. To maintain optimum performance and minimize wear, clean your lighting products at least twice a month. However, be aware that usage and environmental conditions could be contributing factors to increase the cleaning frequency.
Returns Returns Send the product prepaid, in the original box, and with the original packing and accessories. Chauvet will not issue call tags. Call Chauvet and request a Return Merchandise Authorization (RMA) number before shipping the product. Be prepared to provide the model number, serial number, and a brief description of the cause(s) for the return.