LTPH-UM-1214-02
Table 13. Error Acronyms Used on the DS1 Performance History Screens
Error
Description
Acronym
CV-L
Code Violation - Line
Total BPV count.
ES-L
Errored Seconds - Line
Seconds with BPV ≥ 1.
SES-L
Severely Errored Seconds - Line
Seconds with BPV plus EXZ ≥ 1544 or
LOS ≥ 1.
H2TU-C-388 List 7F
Figure 17. H2TU-R DS1 Current Statistics
Figure 18. H2TU-C DS1 Current Statistics
(a)
July 21, 2003
Monitoring System Activity and Performance
Error
Description
Acronym
UAS-P
Unavailable Seconds - Path
A second of unavailability based on SES-P or
AIS ≥ 1.
(b)
PRM-NE
Performance Report Monitoring - Near End
The PRM registers in the ESF/FDL from CPE
indicate errors, and the signal received from the
network at the remote is error-free.
(b)
PRM-FE
Performance Report Monitoring - Far End
The PRM registers in the ESF/FDL from the network
indicate errors, and the signal received from the
CPE is error-free.