andrews MAXXflo EVO Lite Installation And Maintenance Manual page 92

High efficiency condensing stainless steel direct storage water heater
Hide thumbs Also See for MAXXflo EVO Lite:
Table of Contents

Advertisement

Error
Error Code De-
Code
scription
317
Grid frequency out-
side permitted range
324
Input BX, same sen-
sors
325
Input BX/extension
module, same sen-
sors
327
Extension module,
same function
335 /
Sensor input BX21 /
336
BX22 without func-
tion
384
Extraneous light
385
Mains under voltage
386
Fan speed tolerance
432
Function earth not
connected
433
Heat exchange tem-
perature
NA
DHW Operating
mode locked
11 Troubleshooting
Diag.
Notes
Code
275
The frequency (Hz) of the electrical supply is outside permitted tolerance.
461
Check electrical supply to heater.
110
BX sensor duplicated - Two sensor inputs have been defi ned twice with the
same sensor type (e.g. B3). Review last parameters programmed to remove
duplication.
Any
Input BX expansion module 1 sensor duplicated - Two sensor inputs have
been defi ned twice with the same sensor type (e.g. B3). Review last param-
eters programmed for the expansion module to remove duplication.
Any
AGU2.5 expansion module function duplicated - check parameter setup (in
"Confi guration" menu)
211 /
A sensor has been detected connected to BX21 of the AGU2.5 expansion
212
module 1, but not defi ned. Defi ne the sensor using the parameters or remove
the sensor if not required.
213
As above except the undefi ned sensor is connected to an AGU2.5 expansion
214
module 1. The AGU2.5 expansion module should be defi ned as module 1 -
215
Check the dip switches on the front of the device is set correctly
216
252
Ionisation current detected before whilst in standby mode. Check ionisa-
393
tion current ("Diagnostics producer" parameter 8329). If the current present
is greater than 0.61 whilst the burner is in standby, turn off the gas supply to
check gas valve is closing completely. If current is still present, remove ionisa-
tion probe and use a screwdriver to clear the opening through the burner door
before replacing the probe and testing again.
Persistent errors may indicate that the burner is only operational for very short
periods. Try increasing the switching diff erential by at least 1
5024) to increase burner run time.
Other
Ionisation current detected during ignition phase before the gas valve is
opened.
554
Mains voltage below 185v - check electrical supply to the appliance.
555
388
Fan outside allowed speed tolerance during standby phase
531
Fan outside allowed speed tolerance during pre-purge phase
389
374
Fan outside allowed speed tolerance during ignition phase.
383
384
375
Fan outside allowed speed tolerance during min modulation phase.
386
385
Fan outside allowed speed tolerance during max modulation phase.
532
Fan outside allowed speed tolerance during post-purge phase
534
382
390
Other
Check connections and wiring loom of the fan. Replace fan if no fault found.
If necessary use parameter 9650 Chimney drying mode to test the function of
the fan without having to operate the burner.
Any
No Ignition earth, X1 / X17 not connected or earth fault. Check internal and
external earth wiring to the heater
Any
Heat exchanger temperature is too high. Investigate all sources of overheating.
When the issue has been resolved examine the heat exchanger for damage
before putting back into operation.
Any
Check to see if the remote enable link wire is fi tted or external controls wired to
these terminals are closing this circuit. To activate DHW operation this circuit
must be closed.
92
O