andrews MAXXflo EVO Lite Installation And Maintenance Manual page 56

High efficiency condensing stainless steel direct storage water heater
Hide thumbs Also See for MAXXflo EVO Lite:
Table of Contents

Advertisement

CATEGORY: II2H3P
FLUE TYPES: B23,C13,C33,C53,C63
0558-22
0063-22
LPG ONLY ADJUSTED FOR G31 @ 37mbar
CATEGORY: II2H3P
FLUE TYPES: B23,C13,C33,C53,C63
0558-22
MAXXflo EVO Lite
MODEL:
7800598
SC 15/201
NG ONLY ADJUSTED FOR G20 @ 20mbar
HEAT INPUT (GROSS)
Q(Hs)=
15.0kW
HEAT INPUT (NET)
Q(Hi)=
13.5kW
MAXXflo EVO Lite
MODEL:
HEAT OUTPUT
P=
14.7kW
SC 15/201
CO
MAX RATE
10.0% (± 0.2%)
2
HEAT INPUT (GROSS)
Q(Hs)=
HEAT INPUT (NET)
Q(Hi)=
This appliance may only be installed in a room which complies with the
appropriate ventilation requirements. Read the technical instructions before
HEAT OUTPUT
P=
installing this appliance.
CO
MAX RATE
2
CONDENSING APPLIANCE
MAX WORKING PRESSURE (UNVENTED)
5.5 bar
This appliance may only be installed in a room which complies with the
MAX WORKING PRESSURE (VENTED)
6.0 bar
appropriate ventilation requirements. Read the technical instructions before
CAPACITY
200 Litres
installing this appliance.
POWER SUPPLY
230V ~ 50Hz, IP20, 66W
PIN CODE (UKCA / CE)
0558DM2335
CONDENSING APPLIANCE
COUNTRIES OF DESTINATION
UK + IE
MAX WORKING PRESSURE (UNVENTED)
5.5 bar
MAX WORKING PRESSURE (VENTED)
6.0 bar
2022
CAPACITY
Serial
12345678
200 Litres
Year:
POWER SUPPLY
No:
230V ~ 50Hz, IP20, 66W
PIN CODE (UKCA / CE)
0558DM2335
COUNTRIES OF DESTINATION
UK + IE
Manufactured by Malvern Boilers Ltd, Malvern, WR14 1BW, for:
Baxi Heating UK Ltd, Coventry Road, Warwick, UK CV34 4LL
2022
Serial
12345678
Year:
No:
Manufactured by Malvern Boilers Ltd, Malvern, WR14 1BW, for:
Baxi Heating UK Ltd, Coventry Road, Warwick, UK CV34 4LL
7 Commissioning
i
j
k
l
0063-22
3
-22
b
bar
7800598
8
8
15.0kW
13.5kW
14.7kW
9.0% (± 0.2%)
%
%)
o
re
W
W
M10383A
M10383A
03
383A
m
8. Before re-assembly examine the condition of the cork gasket (i) and
replace if it is damaged.
9. Re-assemble the venturi between the fan and gas valve and secure
onto the fan using 2 screws.
10. Ensue the cork gasket between the fan and the venturi is correctly
positioned by inserting a screw through the venturi (j) to hold the
gasket in position.
11. Re-secure the venturi to the gas valve with the remaining 3 screws,
ensuring that the rubber seal and orifi ce remains in place inside the
gas valve.
12. Replace the air intake hose and secure onto the venturi using the
hose clip. Use a pair of pliers to open the clip when fi tting.
13. Initially turn the throttle adjustment screw (k) according to the
following table:
Tab. 34
Model
G20 to G31 Initial
2.5 rotations
throttle adjustment
anti-clockwise
G31 CO
Combustion
2
setting (+/- 0.2%)
14. Follow the commissioning procedure in section 7.2 with the
exception that the
CO
in the table above.
Important
It should not be necessary to turn the throttle screw more than
two turns away from the initial adjustment setting to achieve
ignition. If this is the case, ensure that the components are
refi tted correctly and also be aware that the gas carrying pipes
may need purging before gas is available for ignition at the
burner.
15. Whilst the burner is operating check for the smell of gas around the
gas valve and fan. If gas is detected remove the venturi and check
that it is properly seated onto the fan and gas valve.
16. Affi x the new G31 gas data plate label supplied with the heater over
the top of the existing G20 gas data plate (l).
17. Fit the red octagon warning label (m) to the heater cover.
56
SC15
SC25
No initial adjustment necessary
Case open 9.9%
Case closed 10.0%
combustion setpoint should now be as listed
2
SC35
SC45
Case open 10.0%
Case closed 10.1%
MAXXfl o EVO Lite