C 13 C 33 C 53 C 63 Flue Terminal Positions - andrews MAXXflo EVO Lite Installation And Maintenance Manual

High efficiency condensing stainless steel direct storage water heater
Hide thumbs Also See for MAXXflo EVO Lite:
Table of Contents

Advertisement

Tab. 25
Code Description
A
Directly below an opening, air brick, opening window etc
B
Above an opening, air brick, opening window etc
C
Horizontally to an opening, air brick, opening window, door
D
Below gutters, soil pipes or drainpipes
E
Below eaves
F
Below a balcony or car port roof
G
Above ground, roof or balcony level
H
From vertical drain or soil pipe
J
From an internal or external corner or to a boundary alongside
the terminal
K
From a terminal facing a terminal
L
Vertically from a terminal on the same wall
M
Horizontally from a terminal on the same wall
N
From a surface or a boundary line facing a terminal
P
From a opening in a carport (e.g. door, windows) into the building
Q
Above a pitched roof
R
From an adjacent wall (edge of terminal) or a vertical structure
on a roof
S
Above a fl at roof
From any other roof fl ue terminal
Not Recommended* - Risk assessment required
6 Installation
6.5.10 C
C
C
13
33
53
Terminals should be so positioned as to avoid products of combustion
entering openings into buildings or other fl ues or vents
42
C
Flue terminal positions
63
Minimum clearance
mm
300
300
300
75
200
200
300
150
300
1,200
1,500
300
600
1,200*
300
300
300
300
MAXXfl o EVO Lite

Advertisement

Table of Contents
loading

This manual is also suitable for:

Sc15/201Sc25/201Sc35/201Sc45/201

Table of Contents