Section #
Reporting Code
[345]-[346]
AC Line Trouble/Rest.
[345]-[346]
Bell Circuit Trouble/Rest.
[345]-[346]
Fire Trouble/Rest.
[345]-[346]
Auxiliary Power Trouble/Rest. aux voltage supply trouble/restoral
[345]
TLM Failure
[346]
TLM Restore
[345]-[346]
Gen System Trouble/Rest.
[345]-[346]
Gen System Supervisory
Trouble/Rest.
[347]
Line 1 or 2 FTC Restoral
[347]
Event Buffer is 75% Full
[347]
DLS Lead In
[347]
DLS Lead Out
[347]
Zone Fault/Rest.
[347]
Delinquency
[347]
Wireless Device Low Battery
Trouble/Rest.
[348]
Periodic Test
[348]
System Test
[348]
LINKS1000/GSM1000 Test
* A/R = alarms/restorals; T/R = tampers/restorals; O/C = openings/closings; MA/R = miscellaneous alarms/restorals; T = test transmissions
***Program the "Fail to close" event code [(4)54] to report either closing or activity delinquency. Make sure your central station is aware of the applica-
Table2: Contact ID Zone Alarm/Restoral Event
Codes (as per ADEMCO):
Program any of these codes for zone alarms/restorals when using the
standard (non-automatic) Contact ID reporting format.
Medical Alarms
(1)AA Medical
(1)A1 Pendant Transmitter
(1)A2 Fail to Report In
Fire Alarms
(1)1A Fire Alarm
(1)11 Smoke
(1)12 Combustion
(1)13 Water Flow
(1)14 Heat
(1)15 Pull Station
(1)16 Duct
(1)17 Flame
(1)18 Near Alarm
Panic Alarms
(1)2A Panic
(1)21 Duress
(1)22 Silent
(1)23 Audible
Burglar Alarms
(1)3A Burglary
(1)31 Perimeter
(1)32 Interior
(1)33 24 Hour
Code Sent When...
AC power to control panel is disconnected or interrupted/
AC power restored (Both codes follow AC Failure Comm.
Delay.)
open or short circuit detected across bell terminals/bell cir-
cuit restored
a trouble occurs/restores on a fire zone
telephone line monitoring trouble (sent via LINKS1000/
GSM1000. Do not program if LINKS1000/GSM1000 not
used)
Telephone line restored
"Service Required" trouble occurs (view troubles using
[*][2])/trouble restored
control panel loses/restores communications with mod-
ule(s) connected to the Keybus
control panel has restored communications to central sta-
tion on line 1 or 2 (after FTC)
event buffer is almost full since last upload
downloading session start
downloading session complete
one or more zones have faults/restored
programmed amount of time (days or hours) for delin-
quency has expired without zone activity, or without system
being armed
wireless zones, panic pendants, handheld keypads, wireless
keys have low battery/all low batteries restored
periodic system test transmission
[*][6] bell/communications test
LINKS1000/GSM1000 test transmission
****Zones are identified, panic pendants, wireless keys, and handheld keypads are not.
(1)34 Entry / Exit
(1)35 Day / Night
(1)36 Outdoor
(1)37 Tamper
(1)38 Near Alarm
General Alarms
(1)4A General Alarm
(1)43 Exp. module failure
(1)44 Sensor tamper
(1)45 Module Tamper
(1)4A Cross Zone Police Code
24 Hour Non-Burglary
(1)5A 24 Hour non-Burg
(1)51 Gas detected
(1)52 Refrigeration
(1)53 Loss of Heat
(1)54 Water Leakage
(1)55 Foil Break
(1)56 Day Trouble
(1)57 Low bottled Gas level
(1)58 High Temp
(1)59 Low Temp
(1)61 Loss of Air Flow
Automatic
Dialer
Contact ID
Direction*
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
MA/R
(4) 54***
MA/R
T
T
T
** UU = user number (user01-42); ZZ = zone number (01-64)
Table 3: SIA Format Automatic Zone
Alarm/Restoral Codes
Zone Definition
Delay, Instant, Interior, Delay Stay/
Away, Interior Stay/Away, 24Hr
Burg.
Standard 24Hr Fire, Delayed 24Hr
Fire
24Hr Supervisory
24Hr Supervisory Buzzer
24Hr Sprinkler
24Hr Gas
24Hr Heat
24Hr Medical
24Hr Emergency (non-medical)
24Hr Waterflow
24Hr Freeze
24Hr Holdup
24Hr Panic
Latching 24Hr
SIA Auto Rep
Codes**
Codes
(3) A1
AT-00/AR-00
(3) 21
UT-99/UJ-99
(3) 73
FT-00/FJ-00
(3) AA
YP-00/YQ-00
(3) 51
LT-00
(3) 51
LR-00
(3) AA
YX-00/YZ-00
(3) 33
ET-00/ER-00
(3) 54
YK-00
(6) 23
JL-00
(4) 11
RB-00
(4) 12
RS-00
(3) 72
UT-ZZ/UJ-ZZ
CD-00
(3) 84
XT-00/XR-00
XT-ZZ/XR-ZZ****
(6) A2
RP-00
(6) A1
RX-00
(6) A3
TX-00
tion of this reporting code.
SIA Auto Rep
Codes*
Zone Alm/Rest.
BA-ZZ/BH-ZZ
FA-ZZ/FH-ZZ
US-ZZ/UR-ZZ
UA-ZZ/UH-ZZ
SA-ZZ/SH-ZZ
GA-ZZ/GH-ZZ
KA-ZZ/KH-ZZ
MA-ZZ/MH-ZZ
QA-ZZ/QH-ZZ
WA-ZZ/WH-ZZ
ZA-ZZ/ZH-ZZ
HA-ZZ/HH-ZZ
PA-ZZ/PH-ZZ
BA-ZZ/BH-ZZ
* ZZ = zones 01-64
37