Assigning Zones To Zone Expanders - DSC Power 864 Installation Manual

Hide thumbs Also See for Power 864:
Table of Contents

Advertisement

System Outputs (all 12 V
PC5020
VAUX:
550 mA.
Subtract the listed rating for each keypad,
expansion module and accessory connected to
VAUX or Keybus.
BELL:
700 mA.
Continuous Rating.
3.0 A.
Short Term. Available only with stand-by bat-
tery connected.
PC5204
VAUX:
1.0 A.
Continuous Rating. Subtract for each device
connected.
3.0 A.
Short Term. Available only with stand-by bat-
tery connected.
PC5208
VAUX:
250 mA.
Subtract for each device connected. Subtract
the total load on this terminal from the
PC5020 VAUX/Keybus output.
PC5108
VAUX:
100 mA.
Subtract for each device connected. Subtract
the total load on this terminal from the
PC5020 VAUX/Keybus output.
PC5020 Device Ratings (@ 12 V
• LCD5500 Keypad: 50 mA
• PC5532 Keypad: 45 mA
• PC5516 Keypad: 45 mA
• PC5508 Keypad: 45 mA
• LCD5500Z Keypad: 85 mA
• LCD5501Z Keypad: 45mA
• PC5532Z Keypad: 85 mA
• PC5516Z Keypad: 85 mA
• PC5508Z Keypad: 85 mA
• PC5108 Zone Module: 35 mA
• PC5108L Downlook Interface: 60 mA
• PC5132 Wireless Module: 125 mA
• PC5204 Output Module: 20 mA
• PC5208 Output Module: 50 mA
• Escort5580 Module: 150 mA
• PC5400 Printer Module: 65 mA
• PC5700 Fire Module: 150 mA
• PC5928 Audio Interface Module: 65 mA
• PC5921 Intercom Audio Station: 20 mA
• PC5921 EXT Door Box Audio Station: 20 mA
• PC5921 EXT/R Door Box Audio Station: 35 mA
• DLM-4L v1.0: 180 mA
Other Devices
Read the manufacturer's literature carefully to determine the
maximum current requirement (during activation or alarm) and
use this value for loading calculations. Do not allow connected
devices to exceed the system capabilities during any possible
operational mode.
I n s t a l l a t i o n a n d W i r i n g : 2 . 5 A s s i g n i n g Z o n e s t o Z o n e E x p a n d e r s
)
DC
)
DC
2.5

Assigning Zones to Zone Expanders

The main panel contains zones 1 to 8. Additional zone expanders
may be added to increase the number of zones on the system.
Each zone expander consists of one group of 8 zones. Each mod-
ule must be set to assign the specific zones to the expander. To
do this, set the jumpers located on the expander to the proper
settings.
NOTE: PC5108 v1.0 and lower modules can only support
the first 32 zones on the Power864 system. PC5108 v1.0 and
lower, PC5108L, PC5700, and PC5720 each enroll as two
expander modules.
NOTE: Before a zone expander will work properly, you
must set the jumpers so the panel can determine the cor-
rect zone assignment.
The following are the jumper settings for different zone assign-
ments for PC5108 v2.0 modules. If you need to enroll PC5108
v1.0, PC5108L, PC5700, or PC5720 modules, please refer to the
appropriate module Installation Instruction Sheet for the correct
jumper settings.
Module Jumpers
J1
J2
ON
ON
OFF
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
OFF
OFF
OFF
The following is a diagrams of the PC5108 zone expander mod-
ules and where the jumper switches are located. Refer to the
Installation Instruction sheet for the module for more informa-
tion.
NOTE: Only jumpers J1, J2, and J3 determine the zone
assignment for the module
System Zones
Assigned
J3
ON
Zones disabled
ON
Zones 09 - 16
ON
Zones 17 - 24
ON
Zones 25 - 32
OFF
Zones 33 - 40
OFF
Zones 41 - 48
OFF
Zones 49 - 56
OFF
Zones 57 - 64
7