DSC Power 864 Installation Manual page 44

Hide thumbs Also See for Power 864:
Table of Contents

Advertisement

Module
Compatible?
Classic Escort (VPM-1)
No
Escort5580
Yes
PC-16 Out
No
PC5100
Yes
PC5108 v1.x
Yes
PC5108 v2.x
Yes
PC5108L
Yes
PC5132 v1.X
Yes
PC5132 v2.X
Yes
PC5132 v3.X
Yes
PC5204
Yes
PC5208
Yes
PC5506
No
PC55XX
Yes
PC55XXZ
Yes
PC5509
No
LCD5500 v1.X
Yes
LCD5500Z v2.X
Yes
LCD5500Z v3.X
Yes
LCD5501Z v1.x
Yes
LCD5501Z v2.x
Yes
LCD600
No
LED615
No
SL-XX
No
PC5400 Printer/
Yes
DVACS Module
v1.X to v2.1
PC5400 Printer/
Yes
DVACS Module v2.2
PC5700
Yes
PC5720
Yes
PC5908
Yes
PC5928
Yes
Links1000
Yes
Links2150
Yes
Links2450
Yes
Skyroute
Yes
DLM-1
No
DLM-4 v1.x
No
DLM-4 v1.0L
Yes
DLM-7
No
©2000 Digital Security Controls Ltd.
Toronto • Canada
www.dscgrp.com
PC5020 Module Compatibility
Comments
Users will not be able to access partitions 3 to 8, and zones 33 to
64 through Escort5580 versions 2.x and lower. Only partitions 1
and 2, and zones 1 to 32 are supported on these versions.
Can only add addressable devices to the first 32 zones.
Can only support the first 32 zones. Enrolls as two expander mod-
ules - each module will use up two supervisory slots.
Can only be assigned zones from 1 to 32. Will not support zones
33 to 64. Camera scripts can only be run for zones 1 to 32.
Enrolls as two expander modules - each module will use up two
supervisory slots.
No support for Wireless Keys, Pendants or Handheld Keypads.
Only the first 32 zones can be used as wireless zones.
No identified Wireless Keys support. Only the first 32 zones can
be used as wireless zones.
Only the first 32 zones can be used as wireless zones.
No Keypad zone support. Can only be used on Partition 1 and
Partition 2, and the first 8, 16, or 32 zones.
Can only be used on Partition 1 and Partition 2, and the first 8,
16, or 32 zones.
No Keypad zone support. Some display messages not supported.
Can only be used on Partition 1 and Partition 2, and the first 32
zones.
Can only be used on Partition 1 and Partition 2, and the first 32
zones.
Can only be used on Partition 1 and Partition 2, and the first 32
zones.
Some printing messages not supported. Some events not sup-
ported.
Some events not supported.
Enrolls as two expander modules - each module will use up two
supervisory slots.
Enrolls as two expander modules - each module will use up two
supervisory slots.
Only Partition 1 and Partition 2, and the first 32 zones are
supported.
Only Partition 1 and Partition 2, and the first 32 zones are
supported.
Some events not supported.
Some events not supported.
Some events not supported.
Printed in Canada 29004826 R002