Trial Run; Trim Run; Saving The Result - Fluke VIBXPERT II Operating Instructions Manual

Dual channel fft data collector and signal analyzer
Hide thumbs Also See for VIBXPERT II:
Table of Contents

Advertisement

2-16
2-plane balancing
Input of trial weight in plane B
Imbalance in planes A and B
with trial weight in plane B
'AA': Result in plane A
'AB': Result in plane B
(trial weight always in plane A)

Trial run

The trial run is divided into two parts which are marked in the main
screen as "1A" or "1B":
The trial weight is attached in
1A:
sured in both planes.
The trial weight is attached in
1B:
in both planes.

Trim run

Enter the balancing weights for both planes in the data screen of the
trim run (see next page). Press the right navigation key to mark the
input fields of the series.
Continue the trim run until the residual imbalance is within the toler-
ance range.

Saving the result

1. Press the MENU button in the data screen.
2. Click on 'Save' to open the text editor.
3. Enter a name.
4. Finally press the MENU button and click on 'OK'.
Current balancing plane
is marked:
blue (A)
or
green (B)
Left:
Right:
Trial run 1B
and its influence is mea-
plane A
and its influence measured
plane B

Advertisement