3.5.6
8/16 mA cassette
Figure 3-6: 8/16 mA Cassette (Dark Blue Label) – Code M
A. A certified intrinsically safe isolating amplifier to IEC 60947-5-6
Note
This cassette is suitable for Intrinsically Safe (IS) applications and requires
a certified isolating barrier. See the Rosemount 2130
Certifications
This electronics cassette is also suitable for non-hazardous (safe) area
applications. In this case, U = 11 - 36 Vdc.
It can only be interchanged with a NAMUR cassette.
Table 3-13: Electrical Parameters
Parameter
U
I
ON
I
OFF
I
FAULT
Quick Start Guide
1
2
3
-
+
A
document for Intrinsically Safe approvals.
Value
24 Vdc Nominal
15 - 17 mA
7.5 - 8.5 mA
< 3.7 mA