Specifications - GE NetPro Series User Manual

Table of Contents

Advertisement

g
NetPro model
Ratings
Voltage Amperes (VA)
with computer type load
Watts (W)
with resistive load
Input thermal circuit breaker (A)
Input converter
AC input voltage
AC input voltage range
Maximum start-up AC voltage
Minimum start-up AC voltage
Input current waveform
Input power factor
Input frequency range
Input current (A)
Output converter
AC output voltage
AC output voltage tolerance
Output frequency
Output waveform
Harmonic distortion
Power factor
Crest factor (peak to RMS current)
Capacity appliance outlets
Bypass
AC input voltage range
Frequency tracking rate
Frequency tracking rate
Frequency tracking range
Phase difference
Transfer time
Overload capability
The UPS is fully protected against overload
Overload behaviour:
on-line operation, bypass enabled
on-line operation, bypass disabled
battery operation, NP2000
battery operation, NP3000/4000
bypass operation
Batteries (ratings given for 25°C)
Nominal voltage (V)
Number of 7 Ah batteries
Type
Service life
Battery recharge current
Battery recharge time
Automatic battery test
Runtime in minutes
at typical load (75%)
Watts
60
120
240
360
600
900
1200
1800
General
Weight (kg)
Dimensions (hxwxd, mm)
Enclosure / protection
Environment
Safety
Electromagnetic compatibility
Ambient temperature
Audible noise at 1 meter
Max. relative humidity
OPM_NPE_XXX_2K0_4K0_1GB_V040

8 - Specifications

:
2000
3000
:
2000
3000
:
1200
1800
:
10
14
:
220 - 240 V
:
100% load: 187 - 264 V
60% load: 160 - 264 V
30% load: 125 - 264 V
:
255 V (at any load)
:
187 V (at any load)
:
sinusoidal
:
1
:
50 or 60 Hz ± 10%
:
6.6
10.0
:
220/230/240 V (selectable)
:
± 1%
:
50 or 60 Hz ± 0.15% unless synchronized to the mains
:
sine wave
:
< 2% (typical 1.5%) with linear load
:
0.6
:
up to 6:1
:
max. 10 A per outlet
:
187 - 264 V
:
max. 2 or 10 Hz/sec.(selectable, factory setting 10Hz/sec)
:
2 Hz/sec
:
nominal ± 2%
:
< 7°
:
< 1 msec.
:
110% during 5 minutes, 150% during 2 seconds
:
110% during 110 seconds
:
110% during 5 minutes, >135% during 110 seconds
:
>110% during 110 seconds
:
depends on rating of thermal circuit breaker; typical
:
105% of TCB value: no trip
135% of TCB value: trip within 1 hour
200% of TCB value: for 2 - 30 secs
300% of TCB value: for 0.8 - 4 secs.
:
72
108
:
6
9
:
sealed and maintenance free
:
3 - 6 years (depending on use)
:
1.5 A
:
2 - 6 hours for 80% capacity, std. battery
:
see 3.6.4
:
7
7
190
270
117
165
60
95
38
63
21
35
13
22
9
15
-
9
:
27
38
:
293x220x557
:
steel-plastic / IP20
:
EN 50091-1-1; EN 60950; IEC 950
:
EN 50091-2; EN 50081-1 + EN 50082-1; IEC 801-5: 6kV
:
-10 to +40°C
:
45 dB(A)
The audible noise is load and temperature dependent
:
95% (non-condensing)
19
GE Digital Energy
4000
4000
2400
16
13.5
10 Hz/sec
nominal ± 10%
< 10°
120
10
7
310
185
105
72
40
25
18
10
42
NetPro 2000-4000: user manual 4.0 (GB)