GE Digital Energy NetPro 19" Uninterruptible Power Supply 600 - 1500 VA Manufactured by: GE Digital Energy General Electric Company CH – 6595 Riazzino (Locarno) Switzerland NetPro 19" UPS Technology for the Digital World. Telephone +41 (0)91 / 850 51 51...
Introduction The General Electric (GE) Digital Energy NetPro 19” UPS, a truly on-line uninterruptible power supply, protects your equipment from all forms of power interference, including complete power failures. Safety Rules CAUTION: RISK OF ELECTRICAL SHOCK. The UPS contains batteries. The appliance outlets may be electrically live, even when the UPS is disconnected from the mains.
LED 'on' (8, fig. 6) will blink now: mains power is available and the batteries are charging. If the LED does not blink but illuminates continuously instead, press ‘0’ for one second. GE DE NetPro 19” 600-1500: User manual 3.0 (GB) GE Digital Energy fig. 1...
If electric isolation is required, unplug the power cord from the wall outlet. OPM_NPE_19X_600_1K5_2GB_V030 3 - Operation GE DE NetPro 19” 600-1500: User manual 3.0 (GB) GE Digital Energy fig. 5...
UPS operates on battery (see 3.3.3). To avoid these problems, be absolutely certain that the power demands of the protected equipment are within the limits of the UPS. OPM_NPE_19X_600_1K5_2GB_V030 GE Digital Energy GE DE NetPro 19” 600-1500: User manual 3.0 (GB) fig. 7...
OPM_NPE_19X_600_1K5_2GB_V030 indicating : the bypass switch is : the no-load shutdown is : the output frequency is GE DE NetPro 19” 600-1500: User manual 3.0 (GB) GE Digital Energy LED is active not active active...
This feature reduces the battery recharge time considerably: totally depleted batteries will be recharged to 90% in approx. 1.5 hours, provided that discharging took place at 100% load. OPM_NPE_19X_600_1K5_2GB_V030 GE Digital Energy GE DE NetPro 19” 600-1500: User manual 3.0 (GB)
UPS and the computer (UPS software required). The interface port is operative as soon as the mains power cord is plugged into a live wall outlet, even if the UPS is switched off. We strongly recommend to use only original GE Digital Energy software products in combination with the interface port.
Never short circuit batteries. When working with batteries, remove watches, rings or other metal objects, and only use insulated tools. Battery replacement procedure: see next page OPM_NPE_19X_600_1K5_2GB_V030 6 - Maintenance GE DE NetPro 19” 600-1500: User manual 3.0 (GB) GE Digital Energy...
Page 12
Reinstall battery clamp, do not pinch or clamp the wires. Slide in the battery drawer. Connect the DC connectors, a small spark is normal. Fasten the two screws. Reinstall the front panel. fig. 9 GE DE NetPro 19” 600-1500: User manual 3.0 (GB) GE Digital Energy...
3.2.3) Battery test just after installation Allow the UPS to recharge the or mains failure batteries Battery test shows weak battery Read 6.2, replace batteries GE DE NetPro 19” 600-1500: User manual 3.0 (GB) GE Digital Energy SOLUTION...
420 (without connectors) steel - plastic / IP20 EN 50091-1-1, EN 60950, IEC 950 EN 50091-2 -10 to +40ºC < 45 dB(A), load and temperature dependent 95% (non-condensing) GE DE NetPro 19” 600-1500: User manual 3.0 (GB) GE Digital Energy 1500 1500...