Chapter 5 Operation; Output Mode And Time Delay - Emerson Rosemount 2130 Reference Manual

Level switch vibrating fork
Hide thumbs Also See for Rosemount 2130:
Table of Contents

Advertisement

Reference Manual
00809-0100-4130
5
Operation
5.1

Output mode and time delay

All electronics cassettes have a rotating switch for setting the output to be "Dry On" (on
when the fork is sufficiently dry) or "Wet On" (on when the fork is sufficiently wet).
The electronics uses hysteresis to help prevent constant switching of the output from dry-
to-wet and wet-to-dry states due to splashing or intermediate conditions. To further
prevent false switching, the rotating switch also sets a time delay of up to 30 seconds
before the output changes.
A small cut-out in the rotating switch indicates the present mode and time delay.
Figure 5-1: Top-down View: Example Cassette Inside Housing
A. 'Heartbeat' LED
B. Rotating switch for setting output mode and time delay
The recommended mode for high level alarm installations is the "Dry On" mode
5-2).
Figure 5-2: Typical Settings for High Level Applications
A. Mode "Dry On" and 1 second time delay
The "Wet On" mode is recommended for low level alarm installations
Rosemount 2130 Level Switch
OPERATION MODE
Dry On Mode
Dry
OUT
-
+
Wet
Dry
Wet
Wet On Mode
1
2
3
4
A
Dry On
Wet On
0.3
0.3
1
1
3
3
10
10
30
30
Seconds Delay
A
B
PLC/PNP
Dry On
Wet On
Isolate Supply
Before Removing
0.3
0.3
1
1
3
3
10
10
30
30
Seconds Delay
Operation
May 2022
(Figure
(Figure
5-3).