netvox ZigBee Z308 User Manual

netvox ZigBee Z308 User Manual

Wireless wearable presence tag with emergency button
Hide thumbs Also See for ZigBee Z308:

Advertisement

Quick Links

TM
ZigBee
- Wireless Wearable Presence Tag with Emergency Button
Wireless Wearable Presence Tag
with Emergency Button
Z308
User Manual

Advertisement

Table of Contents
loading

Summary of Contents for netvox ZigBee Z308

  • Page 1 ZigBee - Wireless Wearable Presence Tag with Emergency Button Wireless Wearable Presence Tag with Emergency Button Z308 User Manual...
  • Page 2: Table Of Contents

    5-11. Restore to Factory Setting ....................10 5-12. Offline Activation ........................10 6. Home Automation Clusters for Z308 ....................11 7. Related Netvox Devices ........................14 8. Important Maintenance Instructions ....................14 9. FCC Statement ..........................15 10. CE Certification Statement ......................16...
  • Page 3: Introduction

    1.Introduction Z308, a wearable presence tag, acts as an IAS device for minor children/aged-care use. It is an ideal product to detect one’s presence within/ out of the network coverage for safety purpose. Z308 periodically sends presence/absence report to keep a close watch on those who wear it. Z308 also works as an emergency button.
  • Page 4: Appearance

    2.Appearance Indicator (Red Green Panic Button 3. Features  Fully IEEE 802.15.4 compliant  Utilizes 2.4GHz ISM band; up to 16 channels  IP Rating: IP52  Power supply: 1 x CR2450 3.0V battery  Communication transmission is up to 210 meters linear distance in open field ...
  • Page 5: Installation

    4.Installation...
  • Page 6: Setting Up Z308

    5.Setting up Z308 5-1. Power On Without external power supply, the product uses internal 3V button battery for power supply. Step1. Open the battery back cover Step2. Take a CR2450 button battery, put the negative pole upward into the battery base Step3.
  • Page 7: Enroll In The Zigbee Security System

    Step5. When Z308 can not join a network in 3 minutes, it will go into off mode. To ask for joining Network again, press and hole button for 3 seconds.  After joining a network, Z308 would try to enroll in the ZigBee security system. Please make sure Z308 and CIE (Control and Indicating Equipment) device have enough power.
  • Page 8: Wake Up Z308

    5-6. Wake Up Z308 When users would like to setup or acquire data from the device which is in sleeping mode, we have to wake up the device as the following steps: Step1. Press and hold the Panic Button for 3 seconds. Release the button when the indicator flashes red once.
  • Page 9 Values of the ZoneStauts payload ZoneStatus Meaning Values Attribute Bit Number 1 – opened or alarmed Alarm1 0 – closed or not alarmed 1 – opened or alarmed Alarm2 0 – closed or not alarmed 1 – Tampered Tamper 0 – Not tampered 1 –...
  • Page 10: Presence Tag

    In a security system, it is important that Zone devices report the conditions to the central security unit (the CIE device). To meet this need, Netvox came up with a technique called “HeartBeat”. Right after Z308 enrolls to a security system, it sends a HeartBeat signal to the CIE device. Afterward, it will send HeartBeat data every hour by default settings.
  • Page 11: Restore To Factory Setting

    Function of indicating remaining battery power: In the zone status change notification alarm command sent by Z308 to CIE, the percentage value of the remaining battery power is placed in the high byte of zone status. CIE can understand the battery power of Z308 after receiving it.
  • Page 12: Home Automation Clusters For Z308

    6. Home Automation Clusters for Z308 A cluster is a set of related attributes and commands which are grouped together to provide a specific function. A simple example of a cluster would be the On/Off cluster which defines how an on/off switch behaves.
  • Page 13 Unsigned 0x00 – 0x0003 HWVersion Read only 0x02 8-bit integer 0xff Manu Character 0 – 32 0x0004 facturer Read only netvox string bytes Name Model Character 0 – 32 0x0005 Read only Z308E3ED Identifier string bytes Character 0 – 16...
  • Page 14 Mandatory Identifier Name Type Range Access Default / Optional Battery Unsigned 0x00 – 0x0020 Read / write voltage 8-bit integer 0xff 8-bit 0x0031 BatterySize 0x00 –0xff Read / write Enumeration Battery Unsigned 0x00 – 0x0033 Read / write 0xff Quantity 8-bit integer Battery Bitmap...
  • Page 15: Related Netvox Devices

    0x000… BatteryAlarm 0x003e Read State Bitmap 7. Related Netvox Devices  Z201B: ZigBee HA Coordinator with CIE 8. Important Maintenance Instructions • Please keep the device in a dry place. Precipitation, humidity, and all types of liquids or moisture can contain minerals that corrode electronic circuits.
  • Page 16: Fcc Statement

    9. FCC Statement This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
  • Page 17: Ce Certification Statement

    10. CE Certification Statement...

Table of Contents