Wireless wearable emergency button with inactivity detection
Hide thumbs Also See for R309 Series:

Advertisement

Quick Links

R309 Series
Wireless Wearable Emergency Button with Inactivity Detection
Wireless Wearable
Emergency Button
with Inactivity Detection
R309 Series
User Manual
Copyright©Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in
strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX
Technology. The specifications are subject to change without prior notice.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the R309 Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for netvox R309 Series

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
  • Page 2: Table Of Contents

    Table of Contents 1. Introduction ................2 2. Appearance ................. 2 3. Features ..................3 4. Set up Instruction ................ 3 5. Data Report ................5 5.1 Example of ReportDataCmd ..........6 5.2 Example of ConfigReportReq ..........7 5.3 Example of SetShockSensorSensitivity ....... 8 5.4 Example of SetNoActiveTime ..........
  • Page 3: Introduction

    1. Introduction R309 is a long-distance wireless wearable emergency button device for Netvox ClassA type devices based on LoRaWAN open protocol, which also has an inactivity detection function and is compatible with LoRaWAN protocol. LoRa Wireless Technology: LoRa is a wireless communication technology dedicated to long-distance and low-power consumption. Compared with other communication methods, LoRa spread spectrum modulation method greatly increases to expand the communication distance.
  • Page 4: Features

    ⚫ Low-power consumption, supports longer battery life Note: Battery life is determined by sensor reporting frequency and other variables. Please refer to web: http://www.netvox.com.tw/electric/electric_calc.html In this website, users can find battery lifetime for various models at different configurations. 4. Set up Instruction On/Off Insert two 3V CR2032 button batteries and close the battery cover.
  • Page 5 Network Joining Turn on the device to search the network to join. Never join the network The green indicator stays on for 5 seconds: Success The green indicator remains off: Fail Turn on the device to search the previous network to join. Had joined the network The green indicator stays on for 5 seconds: Success (Not in the original setting)
  • Page 6: Data Report

    Long time inactivity detection function: R309 series has a long-time inactivity detection function. When the vibration sensor on R309 detects the inactivity state has remained for more than the set time (default: 1 hour), it will report an inactivity detection alarm.
  • Page 7: Example Of Reportdatacmd

    Version– 1 byte –0x01——the Version of NetvoxLoRaWAN Application Command Version DeviceType– 1 byte – Device Type of Device The devicetype is listed in Netvox LoRaWAN Application Devicetype doc ReportType – 1 byte –the presentation of the NetvoxPayLoadData,according the devicetype NetvoxPayLoadData– Fixed bytes (Fixed =8bytes) Tips 1.
  • Page 8: Example Of Configreportreq

    byte (1E): Battery – 3.0v, 1E Hex = 30 Dec 30*0.1v = 3.0v byte (01): Emergency Alarm-Alarm byte (00): No Active Alarm- No Alarm ~ 11 byte (0000000000): Reserved 5.2 Example of ConfigReportReq FPort: 0x07 Bytes Var(Fix =9 Bytes) CmdID DeviceType NetvoxPayLoadData CmdID–...
  • Page 9: Example Of Setshocksensorsensitivity

    5.3 Example of SetShockSensorSensitivity FPort: 0x07 ShockSensorSensitivity default = 20 (0x14) Description Device CmdID DeviceType NetvoxPayLoadData SetShockSensor ShockSensorSensitivity Reserved 0x03 SensitivityReq (1Byte) (8Bytes, Fixed 0x00) SetShockSensor Status Reserved 0x83 SensitivityRsp (0x00_success) (8Bytes, Fixed 0x00) R309 0xD3 GetShockSensor Reserved 0x04 SensitivityReq (9Bytes, Fixed 0x00) GetShockSensor ShockSensorSensitivity...
  • Page 10: Example Of Setshocknoworktime

    (5) Set NoActiveTime = 30 min (0x1E) Downlink: 05D3001E00000000000000 // 1E Hex =30 Dec 30*1min = 30min Device return: 85D3000000000000000000 (configuration success) 85D3010000000000000000 (configuration failure) (6) Get NoActiveTime Downlink: 06D3000000000000000000 Device return: 86D3001E00000000000000 (device current parameter) 5.5 Example of SetShockNoWorkTime FPort: 0x07 ShockNoWorkTime: StartHour default = 00:00 (0x00), EndHour default = 06:00 (0x06) Description...
  • Page 11: Example Of Synctime

    5.6 Example of SyncTime FPort: 0x07 Description Device CmdID DeviceType NetvoxPayLoadData SyncTime (4Bytes) Reserved SetSyncTimeReq 0x09 Seconds since gps epoch 1970.1.1 (5Bytes, Fixed 0x00) Status Reserved SetSyncTimeRsp 0x89 (0x00_success) (8Bytes, Fixed 0x00) R309 0xD3 Reserved GetSyncTimeReq 0x0A (9Bytes,Fixed 0x00) SyncTime (4Bytes) Reserved GetSyncTimeRsp 0x8A...
  • Page 12: Example For Mintime/Maxtime Logic

    Status SetButtonPressTimeRsp 0x81 0x00_Success 0x01_Failure Reserved GetButtonPressTimeReq 0x02 (1Byte, Fixed 0x00) PressTime(1byte) 0x00_QuickPush_Less then 1 Second, 0x01_1 Second push, GetButtonPressTimeRsp 0x82 0x02_2 Seconds push, 0x03_3 Seconds push, 0x04_4 Seconds push, (11) Set button press time = 2s Downlink: 0102 Device return: 8100 (configuration success) 8101 (configuration failure) (12) Get button press time Downlink: 0200...
  • Page 13 Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime sleeping (MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and collects data collects data collects data collects data collects data...
  • Page 14: Precautions For Outdoor Installation

    6. Precautions for Outdoor Installation The R309 is IP67 rated device, which means it provides protection against dust and water immersion up to 1m. The test includes water immersion at a depth of at least 1m for 30 minutes or more. The IP67 rated products should be used in indoor environment and sheltered outdoor environment.