netvox RA03A User Manual

netvox RA03A User Manual

Wireless cigarette alarm

Advertisement

Quick Links

Model:RA03A
Wireless Cigarette Alarm
RA03A
User Manual
Copyright© Netvox Technology Co., Ltd.
This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained
in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX
Technology. The specifications are subject to change without prior notice.

Advertisement

Table of Contents
loading

Summary of Contents for netvox RA03A

  • Page 1 This document contains proprietary technical information which is the property of NETVOX Technology. It shall be maintained in strict confidence and shall not be disclosed to other parties, in whole or in part, without written permission of NETVOX Technology. The specifications are subject to change without prior notice.
  • Page 2: Table Of Contents

    Table of Content 1. Introduction ................................2 2. Appearance ................................3 3. Main Feature ................................3 4. Set up Instruction ..............................4 5. Data Report ................................6 6. Installation ................................9 6.1 Installation Location ............................9 6.2 Inappropriate Installation Location ......................... 9 6.3 Install the cigarette alarm ..........................
  • Page 3: Introduction

    1. Introduction RA03A is a wireless cigarette alarm. It is a combination of R311CA and the cigarette alarm. The alarm information of the cigarette alarm is collected via R311CA, and the detected data is transmitted to other devices for display through the wireless network.
  • Page 4: Appearance

    2. Appearance R311CA Indicator Function Key Cigarette Alarm Indicator Cigarette Alarm Test button Sensitivity DIP Switch H: High sensitivity M: Medium sensitivity L: Low sensitivity...
  • Page 5: Main Feature

     Low power consumption and long battery life Note*: Battery life is determined by the sensor reporting frequency and other variables. Please refer to http://www.netvox.com.tw/electric/electric_calc.html. On this website, users can find various types of batteries in different configurations. 4. Set up Instruction...
  • Page 6 Network Joining Turn on the device to search the network. Never joined the network The green indicator stays on for 5 seconds: success The green indicator remains off: fail Turn on the device to search the previous network. Had joined the network The green indicator stays on for 5 seconds: success The green indicator remains off: fail Suggest to check the device verification information on the gateway or consult your platform...
  • Page 7: Data Report

    (1) The device report interval will be programmed based on the default firmware. (2) The interval between two reports must be the minimum time. The reported data is decoded by the Netvox LoRaWAN Application Command document and http://loraresolver.netvoxcloud.com:8888/page/index Data report configuration and sending period are as following: Current Change<...
  • Page 8 (2bytes Unit: s) (2bytes Unit: s) (1byte Unit: 0.1v) (4Bytes, Fixed 0x00) Config Status Reserved 0x81 ReportRsp (0x00_success) (8Bytes, Fixed 0x00) R311CA 0x4C (RA03A) ReadConfig Reserved 0x02 ReportReq (9Bytes, Fixed 0x00) ReadConfig MinTime MaxTime BatteryChange Reserved 0x82 ReportRsp (2bytes Unit: s) (2bytes Unit: s) (1byte Unit: 0.1v)
  • Page 9 Example#2 based on MinTime = 15 Minutes, MaxTime= 1 Hour, Reportable Change i.e. BatteryVoltageChange= 0.1V. MaxTime Sleeping (MinTime) sleeping sleeping sleeping Wakes up and Wakes up and Wakes up and Wakes up and Wakes up and collects data collects data collects data collects data collects data...
  • Page 10: Installation

    6. Installation 6.1 Installation Location Assess where needs to detect the cigarette smoke in the building. The places may include restrooms, staircase corridors of exit, storage rooms, meeting rooms, and other places with fewer people. Install the cigarette alarm near the smoking locations, such as the ceiling above the toilet water tank. The installation location should be at least 10 cm away from the wall or corner.
  • Page 11: Install The Cigarette Alarm

     The high-speed air flow environment near vents, air conditioners, heaters, fans, etc. may keep the smoke away from the device.  The area is without air flow, such as the top part of the building spire, or the top of ceilings and walls. The air is not circulated in these areas, so the smoke cannot enter the device.
  • Page 12: Cigarette Alarm Test

    30 days. When the low-voltage alarm occurs, please replace the battery immediately. Note: 1. RA03A is a combination of R311CA and the cigarette alarm-- NB707V-RL. The power of the two devices is provided by separate batteries. R311CA cannot obtain the battery voltage information of the cigarette alarm; therefore, RA03A reports the voltage information which is from R311CA batteries, and does not include the batteries of the cigarette alarm.
  • Page 13: Important Maintenance Instruction

    7. Important Maintenance Instruction Kindly pay attention to the following in order to achieve the best maintenance of the product: • Keep the device dry. Rain, moisture, or any liquid might contain minerals and thus corrode electronic circuits. If the device gets wet, please dry it completely.