5.8.

Parameters

5.8.1.

Precision

The timing PRECISION (which can be selected at start up, or assigned by default) refers to the
race results
Two calculation modes are available:
«NET TIME» calculation
Ex : with a result to 1/100 sec
Start Time N°121
Finish Time N°121
Result
The last digit of the calculation is truncated.
The times printed will be 10x superior
Here: print = 1:03.218
NET TIMES
NET TIMES + 2 INTER
PARALLEL SEQUENTIAL
TRAINING
Results by default are 1/100 sec
Selectable timing resolution
from 1 sec to the 1/10'000 sec
ATTENTION!
The RS232 and Ethernet ports always communicate the time of day to the PC with the same timing
resolution as giv/on the CP 545's printer.
This avoids calculation and results errors, oft/observed if you compare the results giv/by the
timing device to the software running on your PC.
5.8.2.

Lock Time (multiple impulse filtering)

Lock-out time of the 4 inputs is selectable from 0.01 to 9.99 seconds.
To enter 1.00 sec, press 1 – 0 – 0 and validate with ◄┘.
The minimum lock-out time of 0.01 sec should not be used with any mechanical triggering device
(bounce may cause several impulses received).
ATTENTION
.
TAG Heuer Timing
12:34:56.136
12:35:59.354
With truncation
For your convenience, default lock times are pre-programmed for each timing mode,
and can be modified by you.
Ex : with a result to 1/1000 sec
Start Time N°121
Finish Time N°121
1:03.21
Result
The print of time sure as result will be the same at
1:03.218.
Timing Modes
PTB SEQUENTIAL
PARALLEL DIFFERENTIAL
START – FINISH
START – FINISH + 2 INTER
SPLIT
SPLIT / LAP
JUMPING (3 modes)
Results by default are 1/1'000 sec
Selectable timing resolution
from 1 sec to 1/100'000 sec.
«REAL TIME» calculation
12:34:56.136
12:35:59.354
1:03.218
Without truncation