Mechanical Settings
Î
Changing these settings will affect the operation of the heating/cooling system.
To view and edit these settings:
MENU
1.
Press the
2.
Press and hold the two middle buttons simultaneously until the
3.
Scroll to
System Settings
4.
Scroll to
Mechanical Settings
5.
Scroll to the setting you want to change. Press the plus (
Done
6.
Press the
button when you are finished.
Setting
Range
Type
Gas/Elec or
Heatpump
Fan Type
Gas or Elec
C/O Type
w/Cool or w/
Heat
2nd Stage
Y or N
Heat
Aux Heat
Y or N
(HP)
2nd Stage
Y or N
Cool
Fan Cycler Settings
Î
Changing these settings will affect the operation of the heating/cooling system.
To view and edit these settings:
MENU
1.
Press the
2.
Press and hold the two middle buttons simultaneously until the
3.
Scroll to
Fan Cycler
4.
Scroll to the setting you want to change. Press the plus (
5.
Press the
Done
button when you are finished.
Setting
Range
Fan ON Time
0-120
minutes
Fan OFF Time
10-120
minutes
NOTE:
CONTINUOUS fan mode during COOLING operation may not be appropriate in humid climates. If the indoor air
exceeds 60% relative humidity or simply feels uncomfortably humid, it is recommended that the fan only be used in
the AUTO mode.
button.
and press the
Select
and press the
Default
Gas/Elec
Gas
w/Cool
N
Y
N
button.
and press the
Select
button.
Default
Description
0 (=OFF)
The fan cycler function cycles the HVAC system fan for an ON period followed
by an Off period continuously. Used to provide minimum air ventilation require-
ments. When the Fan ON time is set to a value greater than 0, an additional
10
Cycler FAN mode is present when pressing the FAN button.
Installer Settings
button.
Select
button.
+) or minus (-) button to adjust the setting.
Description
Selects HVAC type, Gas/Electric or Heatpump
Selects the Fan type if system is Gas or Electric
Set the Heat pump Changeover type
Enables the 2nd Stage Heat operation
Enables the Auxiliary Heat operation. Typically the Aux Heat will
be heat-strips in a Heatpump system
Enables the 2nd Stage Cool operation
Installer Settings
+) or minus (-) button to adjust the setting.
menu is displayed.
menu is displayed.