Error Code List
Matrix switcher and external devices
Error code(ASCII)
ER000
ER001
ER002
ER003
ER301
ER302
ER303
ER305
ER309
Example: The command is valid but it cannot be executed.
(1) The unit receives the zoom command while selecting a camera without electronic zoom function.
Transmission Command (ASCII)
Transmission Command (ASCII)
161
Error type
No error
No associated command
Parameter invalid
Receiver buffer's overflow
Command invalid
Parameter invalid
Gateway reception overflow
Gateway timeout error
Internal error
[STX] CMD:R01ZM [ETX]
[STX] ANS:R01ZM:ER301 [ETX]
Meaning
There is no error.
There is no associated command.
The parameter's number, digit and range are invalid.
The receiver buffer has reached overflow capacity.
Invalid operation mode caused the command error.
The parameter's number, digit and range are valid, but the operation mode
is invalid.
Reception buffer overflow has occurred on the other device during the
gateway communication.
Timeout error has occurred during the gateway communication.
The internal processing error has happened.