Operating Modes

Operating Modes

Scan Mode

The imager can be set to operate in one of several scan-
ning modes. See the PRG for more information and set-
tings for any of the options:
Trigger Single (Default) —
cal handheld reader operation. Motion Sense is active and
if the scanner detects motion the aiming pattern is turned
on. When the trigger is pulled, illumination is turned on
and the scanner attempts to read a label. Scanning is acti-
vated until one of the following occurs:
the programmable "maximum scan on time"
has elapsed
a label has been read
the trigger is released
Trigger Pulse Multiple —
is pulled and continues after the trigger is released, until
the trigger is pulled again or until the programmable
"maximum scan on time"
does not disable scanning. Double Read Timeout
vents undesired multiple reads while in this mode.
Trigger Hold Multiple —
ning starts and the product scans until the trigger is
released or "maximum scan on time"
ing a label does not disable scanning. Double Read Time-
1
out
prevents undesired multiple reads in this mode.
Always On —
is always ready for code reading. Double Read Timeout
prevents undesired multiple reads.
Flashing —
The reader illuminator flashes on and off
regardless of the trigger status. Code reading takes place
only during the Flash On
prevents undesired multiple reads.
Stand Mode —
field-of-view. The Aiming Pattern is always on to show
the optimum reading area. If a predefined amount of
movement is detected, the red illumination switches on.
Scanning continues until a label is read or "maximum scan
on time" is reached.
1. See the Product Reference Guide (PRG) for these and
other programmable features
2. Controlled by Flash On Time and Flash Off Time. Use the
PRG to program these options.
18
This mode is associated with typi-
Scanning begins when the trigger
When the trigger is pulled, scan-
The illuminator is always ON and the reader
The scanner looks for changes within its
1
has elapsed. Reading a label
2
time. Double Read Timeout
1
1
has elapsed. Read-
Wasp WDI7500
1
pre-
1
1

Advertisement

Table of Contents
loading

Table of Contents