To protect against risk of fire caused by overloading of power cables, the number of
tiles connected in parallel is limited, see table below.
Tile
IEX1.2
IEX1.5
IEX1.8
IEX2.5
The power limits of the used power connectors needs to be followed.
ESD and LED's:
LED components used in IEX tiles are ESD (Electro-Static Discharge) sensitive. To
prevent the possibility of destroying LED components
do not touch either in operation or while switched off. Always use ESD-gloves.
Disconnect device:
When the appliance inlets of the individual tiles are not accessible, the socket outlets
supplying the rack shall be installed near the equipment and be easily accessible, or a
readily accessible general disconnect device shall be incorporated in the fixed wiring.
This equipment MUST be earthed:
In order to protect against risk of electric shock, the installation should be properly
grounded. Defeating the purpose of the grounding type plug will expose you to the risk
of electric shock.
Power system:
It is recommended to use a TN-S power distribution system (a power distribution
system with a separate neutral and grounding conductor) in order to avoid large ground
current loops due to voltage differences in the neutral conductor. The total electrical
9
Power source
110 – 180 VAC
180 – 240 VAC
110 – 180 VAC
180 – 240 VAC
110 – 180 VAC
180 – 240 VAC
110 – 180 VAC
180 – 204 VAC
Maximum tiles per power cable
USA/Canada
7 tiles
14 tiles
7 tiles
14 tiles
7 tiles
14 tiles
7 tiles
14 tiles
Rest of world
9 tiles
18 tiles
9 tiles
18 tiles
9 tiles
18 tiles
9 tiles
18 tiles
R5915190 /00