REPLACING THE POWER SUPPLY CABLE
Important! This appliance must be connected to the electricity supply only by an
authorised person.
WARNING: If the power supply cable is damaged, it must be replaced only by an
authorised service agent in order to avoid a hazard.
NOTE: The earth conductor must be left about 3 cm longer than the others.
VOLTAGE AND POWER CONSUMPTION
220-240 V ac
FEEDER CABLE SECTION
TYPE
H05V2V2-F
3 x 1,5 mm
2
(*) (**)
(*) Connection possible with plug and outlet
(**) Connection with wall box connection
12
12
2900 W (12.60 A)
(resistance to temperatures of 90°C)