Temporarily Adjusting The Room Temperature; Switching On "Extend Time Phase Once; Switching Off "Extend Time Phase Once - Viessmann VITOCAL 150-A Operating Instructions For The System User

Heat pump control unit with 7" touch display
Hide thumbs Also See for VITOCAL 150-A:
Table of Contents

Advertisement

Setting the heating curve
Tips for setting the "Heating curve"
Room temperature behaviour
The home is too cold during the winter.
The home is too warm during the winter.
The home is too cold during the spring/autumn and win-
ter.
The home is too warm during the spring/autumn and
winter.
The home is too cold during the spring/autumn but
warm enough during the winter.
The home is too warm during the spring/autumn but
warm enough during the winter.

Temporarily adjusting the room temperature

If you wish to adjust the room temperature temporarily,
select the
"Extend time phase once" function. This
function is independent of the time program for room
heating/room cooling.
The rooms will be heated/cooled with the tempera-
ture of the last active time phase for standard room
temperature or comfort room temperature.
If your contractor has not made alternative adjust-
ments, DHW is heated to the selected DHW temper-
ature first, before room heating/room cooling com-
mences.
The DHW circulation pump is switched on (if instal-
led).

Switching on "Extend time phase once"

Tap the following buttons:
1.
for the required heating/cooling circuit

Switching off "Extend time phase once"

The function ends automatically when switching to the
next time phase for standard room temperature or
comfort room temperature.
To terminate "Extend time phase once" early, tap
the following on-screen buttons:
1.
for the required heating/cooling circuit
(cont.)
Room heating/room cooling
Remedy
Set the "Slope" to the next level up.
Set the "Slope" to the next level down.
Set the "Level" to a higher value.
Set the "Level" to a lower level.
Set the "Slope" to the next level down and "Level" to
a higher value.
Set the "Slope" to the next level up and "Level" to a
lower value.
2.
The temperature of the last active time phase for
standard room temperature or comfort room tem-
perature will be set.
2.
27