Electrical Parameters; Sdm-Sio1A Current Consumption - Campbell SDM-SIO1A Instruction Manual

Serial input/output module
Hide thumbs Also See for SDM-SIO1A:
Table of Contents

Advertisement

2.2 Electrical parameters

2.2.1 SDM-SIO1A current consumption

General currents
Standby current
RS-232 and RS-485 current consumption
Idle current
Idle current (receive only)
Active current (RS-232)
Active current (RS-485)
Line load currents
RS-232 line load
RS-485 line load
(2)
Both transmit and receive buffers are fill and discard type, i.e. once the
buffers become full no new information is accepted and all further data is
discarded until space is made when the logger requests data from the
SDM-SIO1A.
Nominal
110 uA
(1)
4.8 mA
3.2 mA
9.6 mA
11.7 mA
2 mA per
load
40 mA
(3)
(1)
All currents are measured with no loads connected
(2)
The RS-485 transmit pair is disabled when not transmitting in order to save power higher
value resistors can be used to save power dependent upon the application. For many
applications, especially with shorter cable runs, no load/termination resistors will be needed.
(3)
Single 100R load between transmit lines. Two 100R resistors (one on each end) is the
maximum recommended loading. Removing any termination resistance should dramatically
decrease current consumption during transfer of data
(4)
The RS-485 interface is protected against short circuits via a 44R resistance making this the
maximum current possible even during short circuit. This resistance is part of the ESD
protection circuitry and will be present at all times; it shouldn't affect normal circuit
operations. The 'RS-485 internal circuit diagram' on p.9 of this manual shows the circuit in
detail.
Max
Notes
150 uA
Current after SerialClose has been called.
6 mA
After SerialOpen has been called
4.5 mA
After SerialOpen in receive only mode
12 mA
Active RS-232 command
13 mA
Active RS-485 command (no termination
resistors)
_
Average expected increase in drawn
current per RS-232 line connected in idle
or active modes (no extra current in
stand-by mode).
Both TX and RTS are considered to be
RS-232 loads.
77 mA
(4)
This extra current is only present when
actively transmitting
User Guide
3