Installation - FIP FLS F6.61 Manual

Hot tap flow magmeter
Table of Contents

Advertisement

DIMENSIONS

INSTALLATION

Pipe Location
• The six most common installation configurations shown in fig. 1 help in
selecting the best location in the pipeline for paddlewheel flow sensor as well
for magmeter flow sensor.
• The three configurations in fig. 2 ensure that the pipe is always full: for a
correct measurement the sensor can NOT be exposed to air bubbles at any
time.
• The three installations in Fig. 3 should be avoided unless you are absolutely
sure the sensor is not exposed to air bubbles.
• In gravity-flow systems the connection to the tank must be designed so the
level does not drop below the outlet: this to avoid pipe to draw air in from the
tank causing a inaccurate measurement of sensor (see Fig. 4).
• For more information, please refer to EN ISO 5167-1.
• Always maximize distance between flow sensors and pumps.
1
Magmeter electronic device
2
Sliding rod
3
AISI 304 SS joint for sensor installation
4
Pressure intake
5
Process connection 1 ¼" gas threaded
6
AISI 304 SS adjustable sensor body
7
AISI 316 L electrodes and PVDF bottom