F6.61 K-FACTOR TABLE (ONLY FOR FREQUENCY
OUTPUT)
K-Factor is the number of pulses which a sensor produces for one liter of
measured fluid. Here below all K-Factors for water at room temperature are
listed.
K-Factor values can depend on the installation conditions. K-Factor has to
divide the frequency generated by F6.61 in order to achieve the flow rate (l/s).
Please contact your dealer for K-Factor values not included in the table.
Installation on cast iron pipes
Metal Strap-on saddles
DN/
Part No.
Size
SZIC080IHT
80
SZIC100IHT
100
SZIC125IHT
125
SZIC150IHT
150
SZIC200IHT
200
SZIC250IHT
250
SZIC300IHT
300
SZIC350IHT
350
SZIC400IHT
400
SZIC450IHT
450
Installation on cast iron pipes
Metal Strap-on saddles
DN/
Part No.
Size
WAIXHT
350
WAIXHT
400
WAIXHT
450
WAIXHT
500
WAIXHT
600
WAIXHT
700
WAIXHT
800
WAIXHT
900
O.D.
O.D.
K-Factor
min
max
88
104
20,22
112
126
12,99
140
154
5,31
168
234
3,67
218
286
2,03
272
344
1,31
322
384
0,9
425
458
0,67
406
472
0,53
475
516
0,4
d/R
K-Factor
0,67
0,53
0,4
0,34
0,23
-
-
-
Installation on other metal pipes
Metal Strap-on saddles
DN/
Part No.
Size
SZIC080IHT
80
SZIC100IHT
100
SZIC125IHT
125
SZIC150IHT
150
SZIC200IHT
200
SZIC250IHT
250
SZIC300IHT
300
SZIC350IHT
350
SZIC400IHT
400
SZIC450IHT
450
d/R
K-Factor
19,02
11,28
4,83
3,31
1,95
1,24
0,88
0,73
0,54
-