TECHNICAL DATA

General
• Pipe Size Range: DN50 to DN900 (2" to 36"). Special version on request for
other sizes. Please refer to Installation Fitting section for more details
• Max Flow Rate Range:
from 0.05 to 8 m/s (0.15 to 26.24 ft/s)
• Full Scale: 8 m/s (26.24 ft/s)
• Linearity: ± 1% of reading + 1,0 cm/s
• Repeatability: ± 0.5% of reading
• Enclosure: IP65
• Materials:
- case: PC/ABS
- gasket: EPDM
• Wetted Materials:
- sensor body: 304 SS/PVDF
- o-rings: EPDM or FPM
- electrodes: 316LSS
Electrical
• Power Supply:
- 12 to 24 VDC ± 10% regulated (reverse polarity and
short circuit protected)
- maximum current: consumption: 250 mA
- protective earth: < 10 Ω
• Current output:
- 4-20 mA, isolated
- max. loop impedance: 800 Ω @ 24 VDC - 250 Ω @ 12 VDC
- positive or negative flow indication
• Solid State Relay output:
- user selectable as MIN alarm, MAX alarm,
Volumetric, Pulse Out, Window alarm, Off
- optically isolated, 50 mA MAX sink, 24 VDC MAX
pull-up voltage
- max pulse/min: 300
- hysteresis: User selectable
• Open Collector output (Frequency):
- type: Open Collector NPN
- frequency: 0 – 800 Hz
- max. pull-up voltage: 24 VDC
- max. current: 50 mA, current limited
- compatible with FLS M9.02, M9.03, M9.50, M9.07, M9.08 and M9.10.
• Open Collector output (Direction):
- type: Open Collector NPN
- max. Pull-up Voltage: 24 VDC
- max. Current: 50mA, current limited
- flow direction:
0 VDC arrow-wise
+ VDC anti arrow-wise
3