Technical Data - FIP FLS F6.60 Manual

Flow magmeter
Table of Contents

Advertisement

technIcal Data

General
• Pipe Size Range: DN15 to DN600 (0.5" to 24")
• Max Flow Rate Range:
from 0.05 to 8 m/s (0.15 to 26.24 ft/s)
• Full Scale: 8 m/s (26.24 ft/s)
• Linearity: ± 1% of reading + 1,0 cm/s
• Repeatability: ± 0.5% of reading
• Enclosure: IP65
• Materials:
- case: PC/ABS
- gasket: EPDM
• Wetted Materials:
- sensor body: 316L SS/PVDF; 316L SS/ PEEK; CuNi alloy/PVDF
- o-rings: EPDM or FPM
- electrodes: 316L SS or CuNi alloy
Electrical
• Power Supply:
- 12 to 24 VDC ± 10% regulated (reverse polarity and short circuit protected)
- maximum current: consumption: 250 mA
- protective earth: < 10 Ω
• Current output:
- 4-20 mA, isolated
- max. loop impedance: 800 Ω @ 24 VDC - 250 Ω @ 12 VDC
- positive or negative flow indication
• Solid State Relay output:
- user selectable as MIN alarm, MAX alarm, Volumetric, Pulse Out, Window
alarm, Off
- optically isolated, 50 mA MAX sink, 24 VDC MAX pull-up voltage
- max pulse/min: 300
- hysteresis: User selectable
• Open Collector output (Frequency):
- Ttype: Open Collector NPN
- frequency: 0 – 800 Hz
- max. Pull-up Voltage: 24 VDC
- max. Current: 50 mA, current limited
- compatible with FLOWX3 M9.02, M9.03, M9.50
• Open Collector output (Direction):
- type: Open Collector NPN
- max. Pull-up Voltage: 24 VDC
- max. Current: 50mA, current limited
- flow direction:
0 VDC arrow-wise
+ VDC anti arrow-wise
3