ThermalTronix TT-L-UTCM Series Thermal Imaging Camera User Manual...
Page 2
Warnings Please avoid aiming the lens at extreme high temperature radiation source, such as the sun, molten steel or laser in any situation; otherwise, the detector may be damaged. Please do not touch the lens to avoid contaminating and damaging. Please pay attention to protect the lens to avoid causing abrasion, scratches even breaches, otherwise, it will affect the device performance badly, even damage the device.
Definition List: Item Name Instruction Note Video Analog video Video GND RS485- RS485B RS485+ RS485A ALARM+ Alarm switch output Open ALARM- Alarm switch output Power GND DC+12V DC12V input 2.2 Dimensions Product outside dimension refer to illustration below...
Call preset 108 changes to baud 2400 Call preset 109 changes to baud 4800 Call preset 110 changes to baud 9600 E、call preset to change the address of thermal camera Call preset 111 to changes to address 1 Call preset 112 to changes to address 2 Call preset 113 to changes to address 13 ……...
Page 9
Press key “LENS-” move the cursor ,Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is 。Auto save when exit 1、Auto: XXX Display the current image auto mode. Three options: 0: manual gain, manual brightness; 1: manual gain, auto brightness; 2: auto gain, auto brightness;...
3.2 Sub-menu operations In the main menu, move the cursor to “Settings “option, press” Focus+” or “Focus-” show the password dialogue,Input the password, refer to Pic 2 Pic 2 Press key : “FOCUS+、FOCUS-、FOCUS+、FOCUS-、FOCUS+、FOCUS-” ,to enter ,refer to Pic 3: Pic 3...
Page 11
Press key “LENS-” move the cursor ,Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is 。Auto save when exit 1、 COM: press key “FOCUS+” or “FOCUS-” show the password dialogue, Input the password “FOCUS+、FOCUS-、FOCUS+、FOCUS-、FOCUS+、FOCUS-” enter the level 3 sub menu 2、...
show the status of gray alarm :N/Y 7、 Alarm:X N: off; (Default) Y: On 8、 E:X Show the status of image enhancement,setup as C/1/2; C: Close; (default) 1/2:Open relatively Gain grade factory default ,including auto,polarity,alarm range,calibration,image, 9、 Backup: alarm,alarm pixel Number。 10、...
Pic 4 In the menu “COM” , Press key “LENS-” move the cursor , Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is 。Auto save when exit 1、ID:XXX ADD:0~254。 2、BaudRate:XXX Baud :1200,2400,4800,9600,14400,19200,38400。 3、Protocol: PELCO-D/P。 4、Exit: Press key LENS+ to exit Default:Add:1 Baud:2400 Protocol: PELCO-D...
Page 14
password. “FOCUS+、FOCUS-、FOCUS+、FOCUS-、FOCUS+、FOCUS-” enter the sub menu Second: : After login Sub-menu. press the key “LENS- “move the cursor to “Mode” key. press key “FOCUS+” or “FOCUS-” show the password dialogue,Input the password. “FOCUS+、FOCUS-、FOCUS+、FOCUS-、 FOCUS+、FOCUS-” enter the level 3 sub menu. Refer to Pic 5 Pic5 In the menu “Mode”...
3.5 Alarm Valve sub-menu First:Without the menu call preset 100. Enter the main menu. In the main menu, press the key “LENS- “move the cursor to “setup” ,press key “FOCUS+” or “FOCUS-” show the password dialogue,Input the password. “FOCUS+、FOCUS-、FOCUS+、FOCUS-、FOCUS+、FOCUS-” enter the sub menu Second:After login Sub-menu.
Page 16
。Show and setup for minimum pixel number of alarm. 3、AlarmPIX:XXX Such as alarm Number 2 .so the alarm pixel is 2* 2. totally 4 pixels 4、Exit: Press key LENS+ to exit。 Default: Alarm range and alarm valve :(grade 1: 650, relatively temperature difference is 30 ℃; Grade 2:1050, relatively temperature difference is 45 ℃;...
5. Troubleshooting Please follow the below table to diagnose and solve the problem. If problem is still exited, please contact our service center. Trouble Reasons and solutions Power cable is not connected correctly The camera can not power →Connect the power cable again ...