  • Page 1 ThermalTronix TT-1007D-MARINE Thermal Imaging Camera User Manual...
  • Page 2 Statement: 1. The contents of this manual will be updated from time to time, updated content will be added in the new version of the manual, without prior notice. 2. This manual may contain technical inaccuracies or typographical errors. Safety precautions: When installing the device, please ask qualified service personnel or system installers to operate The equipment should be installed in a lightning protection environment.
  • Page 3: Table Of Contents

    Contents 1 OVERVIEW ............................... 3 1.1 F ............................. 3 EATURES 1.2 A ............................4 CCESSORIES 2 STRUCTURE AND CABLE DEFINITION ..................... 5 2.1 PTZ ..........................5 APPEARANCE 2.2 T ..........................5 RACKER APPEARANCE 2.3 RS422 ....................6 CONTROL KEYBOARD APPEARANCE 2.4 I ........................
  • Page 4: Overview

    1 Overview TT-1007D-MARINE integrate uncooled infrared imaging, high sensitivity and high precision PTZ cameras as system, and can produce clear images in total darkness, mist and other complex environments. The product can be monitored day and night, and can quickly and accurately identify and locate targets.
  • Page 5: Accessories

    1.2 Accessories item Accessory Name Remark TT-1007D-MARINE mounting plate video tracker RS422 keyboard 2 pin power cable AC adapter TT-1007D-MARINE power supply Vehicle power line Air plug cable Air plug extension connect TT-1007D-MARINE and tracker cable Standard power line tracker and keyboard power supply 12V/5A AC adapter cross pan head screws M4*10...
  • Page 6: Structure And Cable Definition

    2 Structure and Cable Definition 2.1 PTZ appearance item definition remark CCD camera Thermal camera Command Indicator twinkle Power-on indicator Normally on 2.2 Tracker appearance Tracker...
  • Page 7: Rs422 Control Keyboard Appearance

    2.3 RS422 control keyboard appearance RS422 control keyboard 2.4 Installation instruction 1. Remove the mounting plate from the package, fix mounting plate on the target with three bolts refer to the installation hole diameter, refer to the image below 2. TT-1007D-MARINE has three columns at the bottom of the body, align columns with rounded end of the positioning hole of the mounting plate, rotate clockwise to the other end, refer to the image below...
  • Page 8 3. Fix TT-1007D-MARINE and mounting plate by cross pan head screws (Fixing Screw), refer to the image below 4. Connect Air plug cable and Air plug extension cable to air socket on the bottom of the TT-1007D-MARINE. Air plug and air socket have a positioning point (marked in red), connect correspondingly.
  • Page 9: Tt-1007D-Marine Connection Definition

    2.5 TT-1007D-MARINE connection definition control cable Cable color RS485+ RS485- Black RS232+ Green RS232- Yellow RS232 ground Black...
  • Page 10: Tracker Interface Definition

    2.6 tracker interface definition Tracker description Connect to Jack image item item definition GND_1 Tracker and load reserved VCC_1 tracker and load reserved power supply GND_2 Motor power TTL_R relative to tracker TT-1007D-MARINE TTL_T relative to tracker VCC_2 Motor power reserved supply SMA plug...
  • Page 11: 422 Keyboard Interface Definition

    2.7 422 keyboard interface definition Keyboard output leads by a 6-pin air socket; connect air plug cable to air socket External air plug cable is defined as follows: item pin definition description cable color DV12V DC 12V power input Black RS422T- Green RS422control cable...
  • Page 12: Operation Key Instruction

    3.2 Operation key instruction Thermal Camera 3.2.1 Thermal camera default setting: baud rate 2400, address 3 Operation key function Call preset 100 enter into menu 1 When no menu, polarity switching aperture-(I-) 2 when entering the menu, move the cursor from top to bottom circulation aperture+(I+) manual calibration...
  • Page 13 RS485 can’t control TT-1007D-MARINE direction when opening gyro or tracking function default state Operation key function direction up Turning up control direction down Turning down control direction left Turning left control direction right Turning right control preset number+ preset Preset setting setting key preset number+ preset Preset delete...
  • Page 14: Tt-1007D-Marine Operation Instruction

    Note: ”-” means the current function is not set or opened,” √”means the current function is in default state, ”open” means the current function is turned on by default, “close” means the current function is turned off by default. 4 TT-1007D-MARINE operation instruction 4.1 Turn on TT-1007D-MARINE Connect the power and video cables correctly, Turn on power, TT-1007D-MARINE automatically start up, power indicator light.
  • Page 15: Focal Length Control

    minutes; if the climate temperature is more than 5°C ,user repower PTZ after excluding mechanical failure, if the self-test still fails, please contact the supplier or manufacturer. note:  If set number 0 as the preset, PTZ will automatically call number 0 preset after self-test is successful.
  • Page 16: Video Switch

    4.4 video switch PTZ default setting: baud rate 2400, address 1. Composite video output can be switched to CCD video or thermal video through the command (manual mode), it can also automatically switch video output (automatic mode) according to light and dark.
  • Page 17: Image Stabilization

    4.7 Image stabilization PTZ default setting: baud rate 2400, address 1. Image stabilization feature is off by default, can be turn on/off by calling number 29 preset. Open the image stabilization function when the image is affected by external jitter, so that the image can be displayed smoothly, but the video resolution will be declined relatively, when the image does not appear jitter, we suggest close the image stabilization feature.
  • Page 18: Thermal Camera Lens Safety Position

    4.10 Thermal camera lens safety position PTZ default setting: baud rate 2400, address 1 STANDBY NOW CALL PRST 66 TO EXIT When the machine is idle, call number 65 preset and move -90 ° vertical, hide thermal imaging camera inside PTZ to protect thermal imaging camera lens, the display will appear hint (as shown), under such circumstances, sending commands to the device camera will not get any action in response.
  • Page 19: Keyboard Operation Instruction

    5 Keyboard operation instruction normal operation instruction operational key function remark ENTER/OPEN reserved RETURN/CLOSE reserved WIDE zoom- TELE zoom+ (16*16,32*32,64*64,128*128) Tracking boxes from small to big Each time press FAR key, tracking box size change accordingly, total of 4 gears NEAR Tracking boxes from big to small...
  • Page 20: Thermal Camera Menu

    6 Thermal camera menu Default address: 3, baudrate: 2400 6.1 Main menu Without the menu call preset , enter the main menu, Main men Press key “LENS-” move the cursor, Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is 。Auto save when exit 1、Auto: XXX Display the current image auto mode.
  • Page 21: Sub-Menu Operation

    5、Z:Y/N Zoom status N:no zoom (default) Y:Zoom 2 times 6、Level:X show the range of alarm:From 1 to 6, default is 4 7、 Setting : Press key “FOCUS+” or “FOCUS-”,show the password dialogue Press “FOCUS+、FOCUS-、FOCUS+、FOCUS-、FOCUS+、FOCUS-” to enter sub menu dialogue 8、 EXIT: Exit the menu Note :...
  • Page 22 Sub menu Press key “LENS-” move the cursor, press key “FOCUS+” or “FOCUS-” to change the value or get into the submenu where the cursor is 。Auto save when exit 1、 COM: Setup the communication parameters. 2、 Mode : Setup the mode parameters. 3、...
  • Page 23: Com Sub-Menu

    Show the status of gray alarm :N/Y 7、 Alarm:X N: off; (Default) Y: On 8、 E:X Show the status of Gain,setup as C / 1/2 C:Close; (default) 1/2:Open relatively Gain grade 9、 Backup: Factory default 10、 Exit :XXX Press key “FOCUS+” or “FOCUS-” to exit 6.3 COM sub-menu First:...
  • Page 24: Mode Sub Menu

    change the value where the cursor is 。Auto save when exit 1、ID:XXX ADD:0~254。 2、BauRate:XXX Baud :1200,2400,4800,9600,14400,19200,38400。 3、Protocol: PELCO-D/P。 4、Exit: Press key LENS+ to exit Default:Add:3 Baud:2400 Protocol: PELCO-D 6.4 Mode sub menu First:Without the menu call preset 100. Enter the main menu. In the main menu, press the key “LENS-“...
  • Page 25: Change Rs485 Configuration

    change the value where the cursor is 。Auto save when exit 1、Gain:XXX Range: 0~255。 2、Bright:XXX Range :0~255。 3、Exit: Press key LENS+ to exit 7 Change RS485 configuration Make sure to change 485 configuration as follow steps, or the camera may work improperly: 1、...
  • Page 26 baud rate.So every time when the device starts up,the first received order protocol and baud rate is the current protocol and baud rate.If user wants to modify protocol or baud rate,restart the device and send order as per new protocol and baud rate.
  • Page 27: Faq

    8 FAQ Please solve by yourself as per below solution when the device has following problems. If can’t please contact supplier problems cause solution can’t self-inspection power adapter fault change power adapter after starting up power line plug loose connect power line RS485 control lines reversed Check control line, ensure or shorted...
  • Page 28: Technical Specifications

    9 Technical specifications Items ThermalTronix TT-1007D-MARINE Sensor type Uncooled FPA microbolometer Resolution 384×288 Pixel size 25μm Spectral range 8~14μm Focal length 37mm Lens type Athermalize, focus-free Thermal Imaging NETD ≤100mk Camera Manual adjust brightness/gain;Automatic Brightness/Gain adjust brightness and manual adjust gain; adjustment Automatic adjust brightness/gain Polarity...