Summary of Contents for Intellisystem ThermalTronix TT-CXL-DVACS Series
Page 1
ThermalTronix TT-CXL-DVACS Series Thermal Camera Specifications User Manual...
Page 2
Intellisystem Technologies. Disclaimer Intellisystem Technologies makes the best to verify the integrity and correctness of the contents in this document, but no formal guarantee shall be provided. Use of this document and the subsequent results shall be entirely on the user's own responsibility. Intellisystem Technologies shall have the right to change the contents of this manual without prior notice for the purpose of enhanced performance.
Page 3
Warnings Please avoid aiming the lens at extreme high temperature radiation source, such as the sun, molten steel or laser in any situation; otherwise the detector may be damaged. Please do not touch the lens to avoid contaminating and damaging. Please pay attention to protect the lens to avoid causing abrasion, scratches even breaches, otherwise, it will affect the device performance badly, even damage the device.
1 Introduction TT-CXL-DVACS Series is composed of uncooled infrared thermal imaging module and visible light camera, which can be applied in the following fields: middle-range power stations, public places; short-range gate of entry and exit, equipment storage sites; day and night to monitor people , vehicles, ships and so on.
1.2 INCLUDED TT-CXL-DVACS Series List for accessories and files: accessory quantity remark PTZ Camera AC24 Power Adapter User manual Packing list qualification...
2 Component names and function 2.1 Device appearance Pic. 1 Description Remark Thermal housing Thermal camera Rear cover Address and function of PTZ DIP switch CCD housing Include CCD camera and protocol board DIP switch cover Definition refers to chapter 5 Wire hole Used to connect power supply, monitor and RS485 control 2.2 Connector definition...
4 Thermal imaging camera menu 4.1 Main-menu operation Before operate thermal camera .please set address 2 firstly Without the menu call preset 100 to activate the main menu. Enter the main menu(pic 2): Pic 2 Press key “LENS-” move the cursor, Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is.
Page 10
N:no zoom (default) Y:2X digital zoom 6、Level:X show the range of alarm:From 1 to 6, default is 4 7、 Seting : Activate the setting secondary menu Press key “FOCUS+” or “FOCUS-”,show the password dialogue Press “FOCUS+、 FOCUS-、 FOCUS+、 FOCUS-、 FOCUS+、 FOCUS-” to enter setting menu dialogue.
4.2 Setting secondary menu In the main menu, move the cursor to “setting” ,press key “FOCUS+” or “FOCUS-” show the password dialogue,refer to Pic 3, Input the password to enter, refer to Pic 4. Pic 3 Pic 4 Press key “LENS-” move the cursor, press key “FOCUS+” or “FOCUS-” to change the value or get into the submenu where the cursor is 。Auto save when exit 1、...
Page 12
4、 Debug: Debug option only for R&D department of manufacturer 5、 RECOVER :H/L/N Setup as H /L/N; Setup as H: Calibrate 1 time during the 1 minute if working time less than 10 minutes. Calibrate 1 time during 2 minutes if working time between 10 and 30 minutes .calibrate 1 time during 5 minutes if working time between 30 minutes and 1 hour.
4.3 Com sub-menu Pic 5 In the menu “COM”(chapter 4.2 shows how to activate the “com” option),Press key “LENS-” move the cursor ,Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is. Refer to Pic 5. Auto save when exit 1、ID:XXX Address of the IR camera:0~254。...
4.4 Mode sub-menu Pic 6 In the menu “Mode” (chapter 4.2 shows how to activate the “Mode” option),Press key “LENS-” move the cursor ,Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is. Refer to Pic 6.Auto save when exit 1、Gain:XXX Range: 0~255。...
4.5 Alarm Value sub-menu Pic 7 In the menu “Avalue” (chapter 4.2 shows how to activate the “Avalue” option),Press key “LENS-” move the cursor , Press key “FOCUS+” or “FOCUS-” to change the value where the cursor is. Refer to Pic 7.Auto save when exit 1、Level:X Range: 1~6。...
5 Change the address of PT system PT System address is minus 1 of thermal camera. Use a Phillips screwdriver to loosen four Phillips Screws on the DIP switch cover (refer to Pic.1), remove the DIP switch cover, you can see the circuit board DIP switch as shown in Pic8. Pic8 Note :1.
6 Change the address of CCD camera CCD camera address is minus 1 of thermal camera, it means CCD camera has the same address as PT system Open housing of CCD camera. Pressing the 『SETUP』 button(refer to Pic 9) on the rear of CCD camera about 2 seconds to popup the menu of the camera.
7 Change the address of protocol board Same with the PT system address. Only reboot the address will be valid after change address. The address switch is interface J3 on the protocol circuit board(Refer to Fig.12) which installed in the CCD camera housing (Refer to Pic.1).
8 Troubleshooting Please follow the below table to diagnose and solve the problem. If problem is still exited, please contact our service center. Trouble Possible cause Solution After power-on, PTZ Power wire connects wrong or Again connect the power wire does not perform not well self-checking...
Need help?
Do you have a question about the ThermalTronix TT-CXL-DVACS Series and is the answer not in the manual?
Questions and answers