0 • INDIVIDUAL PROTECTION EQUIPMENT
Neither the tools nor the individual protection equipment are included in the pack.

Individual Protection Equipment

Helmet
Anti-cut gloves
Reinforced boots
Safety belt
Goggles or shield
Back belt
1 • HYDRAULIC POWER UNIT

1.1. Mechanical assembly

1. The power unit packaging contents the fitting box. Unpack all the assembly and place the
power unit at the final position at the installation correctly supports on its four anti-vibration rubber
feet.
3. Take the hydraulic hose from the hole to connect to
the power unit and to the rupture valve on the cylinder.
V700 - 11/2017
4. Fill the tank
4/40
MP sava3 Hidraulic Power Unit 1 ¼" 1 ½"
2. Fit the lever of the hand pump and connect the
shut-off valve to the input of the power unit
(cylinder and power unit fitting boxes).
STEPS TO FOLLOW
a) Remove the tank cover and check the
cleaning of the tank (dry and no dust)
b) Fill the tank with hydraulic oil avoiding making
bubbles.
c) The oil level must be at least 10 cm higher
than the motor surface level at the moment of
maximum expansion of the cylinder.
MTMECMPsava3_700_EN