Oil Cooling Device; Oil Cooling Device Connections - Hydraulic Power Unit - MP sava3 Technical Manual

Hydraulic power unit
Table of Contents

Advertisement

3 • OIL COOLING DEVICE

3.1 Oil cooling device connections - Hydraulic power unit

OUT
INPUT
V700 - 11/2017
The power unit has a dust protection on
the tank identification cover. Remove this
protection before installing the cooler.
.
IMPORTANT:
The oil cooler must not be placed at a height of more than 1100 mm
with regard to the ground where the hydraulic power unit stands.
COOLER ASSEMBLY
1. Assemble as many hoses as required to enable the
oil input and output from the cooler (see attached table).
2. Insert the IN and OUT hoses of the cooler into the
holes of the tank cover.
3. To assemble the thermostat, see picture here below.
ASSEMBLY DETAIL
REQUIRED ACCESSORIES NOT INCLUDED
INPUT
- SAE 100 Elbow 90º Hydraulic hose
- M G 1" – M G ¾" Connector
- 1" hydraulic joint.
OUTPUT
- SAE 100 Elbow 90º Hydraulic hose
- M G ¾" - M G ¾" Connector
- ¾" Hydraulic joint
ASSEMBLY ON TANK COVER
- 4 T 25-30 Silent-blocks
- 4 DIN 934 M6 nuts
- 4 DIN 7980 Ø6 Grower
- 4 DIN 9021 M6 Washers
18/40
MP sava3 Hidraulic Power Unit 1 ¼" 1 ½"
THERMOSTAT
MTMECMPsava3_700_EN