Testings - MP sava3 Technical Manual

Hydraulic power unit
Table of Contents

Advertisement

2.1.5. Testings

1. Pressure relief valve. Screw 1
1. Load the lift car with 100% of the rated load.
2. Open the manometer protection key and take the pressure reading (full load pressure).
3. Close the shut-off valve and disconnect the maximum pressure reading switch from the circuit if any.
4. Send the lift up and make a note of the manometer reading once it is stabilized (tripping pressure).
5. This pressure should be 1,4 times the full load pressure.
6. If the pressure is not correct, tighten screw 1 to increase the tripping pressure (+ pressure) or loosen to reduce it (- pressure).
2. Maximum or minimum pressure switch (optional)
1. Close the shut-off valve and send the lift up.
2. Note the cut-off pressure; it should be between 1,1 and 1,2 times the full load pressure.
3. If it is not correct, adjust the pressure switch using an appropriate screwdriver; see figure below.
3. Hand pump. Screw 7
1. Pump the lever and check the lift goes up.
2. If not, the hand pump needs priming. To do this, pump the lever while loosening and tightening the bleeding screw several times, until an opposition in
movement is observed. Then tighten the screw.
3. To check the tripping pressure of the relief valve:
Close the shut-off valve and cut off the power.
-
Pump the lever and note the manometer reading after it is stabilized.
-
Pressure should be 2,3 times the full load pressure.
-
-
Should it not be correct, tighten the relief valve screw to increase the tripping pressure, or loosen to reduce it.
Bleeding Hand Pump
Repeat the pump
several times to ensure
the bleeding of the
hydraulic circuit.
V700 - 11/2017
Hand pump
Bleeding
lever
screw
Cylinder minimum
pressure adjustment (6)
Pump with the hand pump and close the bleeding Screw
when the hand pump is loaded.
12/40
MP sava3 Hidraulic Power Unit 1 ¼" 1 ½"
Relief valve screw (7)
Allen Wrench hex.
2 mm
Turn left to decrease
the acting pressure
Unscrew a few turns the
Bleeding Screw. It is not
necessary unscrew it
completely
Open and close several
times the Bleeding Screw
and, at the same time, start
to pump by acting on the
lever of the Hand-Pump.
MTMECMPsava3_700_EN
Remove the cap
Turn right to increase
the acting pressure

Advertisement

Table of Contents
loading