Converting SCSI Configuration from Simplex to Duplex

Accessing a Pedestal Mounted Server

Extend the Server from the Rack

Ensure that there is enough area (Approximately 1.5 meters [4.5 ft.]) to fully extend the server
NOTE
out the front and work on it.
To extend the server from the rack, perform the following steps:
Step 1. Remove the T-25 screws that fasten the server to the rack.
Step 2. Flip out the two pull handles at either end of the front bezel and slowly pull the unit forward by the
handles. The server is fully extended when the rail clips are locked in place. When fully extended,
the front and top covers are fully accessible.
Accessing a Pedestal Mounted Server
The hp Integrity rx4640 server is also designed to be pedestal mounted. It is not necessary to remove the
server from the pedestal to gain access to internal components. The front bezel, front cover, and top cover may
be removed with the pedestal attached to the HP Server.
WARNING
Ensure that the HP Server is properly grounded when performing remove and
replace procedures. Use and antistatic wrist strap and grounding mat similar to
those found in the HP Electrically Conductive Field Service Kit.