USER PROGRAMMABLE CAP
FUNCTION
DSR Jumper for Port A — No Connection
DSR Jumper for Port A — Forced Active
DSR Jumper for Port B — No Connection
DSR Jumper for Port B — Forced Active
3.5 User Programmable CAP to Device
Connection
After the unit is programmed for your application,
you can physically install it.
Connect the unit to the two incompatible devices
with RS-232 cables. Make sure the port configured
for Device A is connected to Device A, and the port
configured for Device B is connected to Device B.
Apply AC Power.
Your unit is ready for operation.
14
Table 3-7 DSR Jumper Settings for User Programmable CAP
JUMPER POSITION
W2 — AB
W2 — BC
W3 — AB
W3 — BC
3.6 Rackmount Application
The Cards (CMA005C) are installed into the
RM010 Rack, which holds up to 12 Cards. For
Rackmount Card Application, the configuration is
idential to the CMA005A configuration.
Remember the neither the CMA005A or
CMA005C are supplied with cables. If
you need cables, you will have to order
them separately.