Switches S1 (Port A) and S2 (Port B)
POSITION
1
2
WORD STRUCTURE
OFF
OFF
1 stop bit
ON
OFF
1 1/2 stop bits
OFF
ON
1 stop bit
ON
ON
2 stop bit
POSITION
3
OFF
Odd parity (See Section 3.4 for
Mark and Space Parity)
ON
Even parity
POSITION
4
OFF
Parity disable (voids Position 3)
ON
Parity enable
POSITION
5
6
OFF
OFF
8 data bits
OFF
ON
7 data bits
ON
OFF
6 data bits
ON
ON
5 data bits
POSITION
7
8
BUFFER FLOW CONTROL
OFF
OFF
Hardware flow control using
CTS/DTR, or no flow control
ON
OFF
ENQ/ACK buffer flow control
OFF
ON
X-ON/X-OFF buffer flow control
ON
ON
X-ON/X-OFF buffer flow control
(CAP transmits an XON code
out the port on Reset, as, after
a power failure.)
NOTE: For all hardware flow control, CTS and DTR Switch 7
options must NOT be in the "forced active" position.
For no flow control and normal software flow controls
(X-ON/X-OFF and ENQ/ACK) the CTS and DTR
Switch 7 options should be in the "forced active" position.
Switch S7 Settings
POSITION
1
RI Input Port A
ON
RS-232 RI connected (custom programming only)
OFF
Forced inactive (Low)
POSITION
2
DTR Output Port A
ON
Controlled by software (hardware flow control)
OFF
Forced always active (High)
POSITION
3
DCD Input Port A
ON
RS-232 DCD Connected (enables Receive data)
OFF
Forced active (High)
POSITION
4
CTS Input Port A
ON
RS-232 CTS connected (enables Transmit data)
OFF
Forced active (High)
POSITION
5
RI Input Port B
ON
RS-232 RI connected (custom programming only)
OFF
Forced inactive (Low)
POSITION
6
DTR Output Port B
ON
Controlled by software (hardware flow control)
OFF
Forced active (High)
POSITION
7
DCD input Port B
ON
RS-232 DCD connected (enables Receive data)
OFF
Forced active (High)
POSITION
8
CTS Input Port B
ON
RS-232 CTS connected (enables Transmit data)
OFF
Forced active (High)
S3 and S4 Switch Settings for Baud Rate and Data Code Set
POSITION
Baud Rate With Baud Rate With
1
2
3
4
Position 5 OFF
Position 5 ON
OFF
OFF
OFF
OFF
38,400
ON
OFF
OFF
OFF
19,200
OFF
ON
OFF
OFF
9,600
ON
ON
OFF
OFF
4,800
OFF
OFF
ON
OFF
4,800
ON
OFF
ON
OFF
2,400
OFF
ON
ON
OFF
2,400
ON
ON
ON
OFF
1,828.72
OFF
OFF
OFF
ON
1,371.54
ON
OFF
OFF
ON
1,200
OFF
ON
OFF
ON
1,037.92
ON
ON
OFF
ON
600
OFF
OFF
ON
ON
300
ON
OFF
ON
ON
200
OFF
ON
ON
ON
164.82
ON
ON
ON
ON
150
NOTE: If your desired baud rate is within ±4% of one listed above, in most
cases you should set the CAP to the listed rate.
Make certain Switches S1 and S2 are set for the correct number of
data bits for the particular Data Code Set chosen (see Table 4-3 and
the code set list in Section 4.4).
P1
B
A
B
ON
DB9
C
S7
CONNECTORS
W3
OFF
A
W2
S1
A B C
User Programmable CAP Circuit Board
The User Programmable CAP
Quick-Setup Sheet
6
7
8
DATA CODE SET
OFF
OFF
OFF
ASCII
1,371.54
1,200
ON
OFF
OFF
EBCDIC
1,037.92
OFF
ON
OFF
TRANSCODE
600
ON
ON
OFF
BAUDOT
300
OFF
OFF
ON
TICKER TAPE
200
ON
OFF
ON
ASCII
OFF
ON
ON
ASCII
164.82
ON
ON
ON
OTHER may be
150
134.28
chosen only if both
110.35
devices use the same
100
code set.
74.42
67.14
55.82
50
45.5
POWER
S6
RXB
TXB
RXA
TXA
RAM
W4
SIZE
C B A
S2
S3
S4
S5
Switch S5 Settings
Mode options, equipment type, transmission mode,
and buffer allocation
POSITION
1
Mode options for PORT A
OFF
Pass-Thru Mode
ON
Program Mode
POSITION
2
Mode options for PORT B
OFF
Pass-Thru Mode
ON
Program Mode
POSITION
3
Equipment type CAP should
emulate (Port A)
OFF*
DCE - When using crossover cable
ON
DTE - When using straight-pinned
cable
POSITION
4
Transmission mode for PORT A
OFF
Full duplex/Simplex
ON
Half-duplex (hardware flow
control configuration must be
used with half duplex.)
POSITION
5
Equipment type CAP should
emulate (Port B)
OFF*
DCE - When using crossover cable
ON
DTE - When using straight-pinned
cable
POSITION
6
Transmission mode for PORT B
OFF
Full duplex/Simplex
ON
Half-duplex
POSITION
7
8
Buffer allocation**
Port A
OFF
OFF
1/2
ON
OFF
3/4
RESET
OFF
ON
1/8
BUTTON
ON
ON
RESERVED
*A CAP crossover cable must be attached to the CAP for it
to emulate DCE in addition to selecting the DIP switch
option to emulate DCE. See the Appendix for more on
cable pinning.
* *Buffer allocation is for data being received by that port,
(input data).
DSR Jumper Settings
W2
DSR Jumper for Port A
A-B
No connection
B-C
DSR always active
W3
DSR Jumper for Port B
A-B
No connection
B-C
DSR always active
Port B
1/2
1/4
7/8