AT Commands
at
at+laddr
at+name
at+name<Parameter>
at+baud
at+baud< Parameter>
at+role
at+role< Parameter>
at+inq
at+sinq
at+conn< Parameter>
RB8762CMF Designer's Guide (RRD2Z50-20180802001-A07-C3)
Supported AT Command List
Slave Side
Master Side
√
√
√
√
√
√
√
√
Invalid
Invalid
Invalid
√
Test UART channel
√
Read BD address
√
Read device name
Set device name(Max. length=16 byte)
Default name is "Radicom".
√
After changing name, you should use
"at+reset\r\n" command and the new name
will work.
√
Check current Baud rate.
Set Baud rate.
Parameter range(1, 2,...,9):
1: 1200bit/s
2: 2400bit/s
3: 4800bit/s
√
4: 9600bit/s
5: 19200bit/s
6: 38400bit/s
7: 57600bit/s
8: 115200bit/s
9: 230400bit/s(USB only)
√
Check the role of device.
Role setting.
Parameter range(0,1,2):
√
0: slave device
1: master device
2: OTA
Get slave device's BD address (Max.=10
√
slave, sequence number 0-9)
Stop searching for BT device. *Must-do
√
step, or master device will keep searching.
Connect a slave device.
√
*Input parameter from "AT+INQ".
Description
17