Provide Machine Protection - Carrier AquaEdge 23XRV Installation Instructions Manual

High-efficiency variable speed screw chiller with greenspeed intelligence and pic6 controls 50/60 hz r-134a
Table of Contents

Advertisement

Nameplate 1: Specifications and Custom Catalog Number
representing options installed at factory.
See Nameplate 2 (Location behind HIM)
for equivalent base catalog number and separate options.
C
Cat No: 20GYAN
UL Open Type/IP00
Rear-UL Type 4X/IP66 with 4X flange kit
Power ND (HD)
Input: 3 Phase 47-63Hz
AC Voltage Range
Amps ND (HD)
Output: 3 Phase 0-400 Hz
AC Voltage Range
Base Frequency (default)
Continuous Amps ND (HD)
60 Sec Ovid Amps ND (HD)
3 Sec Ovid Amps ND (HD)
COOLANT
RATED PRESSURE
Mfd. on 2015/06/24
Allen-Bradley
AB
PRODUCT OF USA FAC 1100
N223
Fig. 9 — VFD Nameplate
CARRIER PART NUMBER
23XRB2AA_ _ _ _ _ _ _ _ _ _ _
23XRB2BA_ _ _ _ _ _ _ _ _ _ _
23XRB2BB_ _ _ _ _ _ _ _ _ _ _
23XRB2CC_ _ _ _ _ _ _ _ _ _ _
NOTE(S):
a. 110% output current capability for one minute, 150% output current for 5 seconds.
Table 2 — Drive Assembly and Power Module Ratings (Std Tier VFD)
CARRIER PART NUMBER
23XS0_ _ _00Y _ _ F0
(Rockwell; S = Air cooled)
NOTE(S):
a. All voltage and current combinations listed may not be available for sale. Please review Carrier Marketing literature for latest offering.
b. 110% output current capability for one minute, 150% output current for 5 seconds.
c. Last character 0 indicates refrigerant-cooled; last digit A indicates air-cooled.
367
ANONNNNNQBQ
Series: A
400V Class
480V Class
200kW (180kW)
300 HP (250 HP)
432-528
342-440
338.9 (283.5)
359.5 (295.9)
0-400
0-460
60 Hz
50 Hz
367 (302)
361 (302)
403.7 (453)
397.1 (453)
550.5 (550.5)
541.5 (543.6)
Treated Water/R134A
185 PSIG
Original Firmware: 11.002
Serial Number: 42127997
Table 1 — Drive Assembly and Power Module Ratings (LF-2 VFD)
VFD
FRAME SIZE
Frame 2AA
Frame 2BA
Frame 2BB
Frame 2CC
ENCLOSURE
TYPE
c
NEMA 1
Recommended Control and Signal Wire Sizes
The recommended minimum size wire to connect I/O signals to
the control terminal blocks is 18 AWG (American Wire Gauge).
Recommended terminal tightening torque is 7 to 9 in.-lb (0.79 to
1.02 N-m).
Recommended Airflow Clearances
Be sure there is adequate clearance for air circulation around the
enclosure. A 6-in. (152.4 mm) minimum clearance is required
wherever vents are located in the VFD enclosure.
Match Power Module Input and Supply Power Ratings
It is important to verify that building power will meet the input
power requirements of the Machine Electrical Data nameplate in-
put power rating. Be sure the input power to the chiller corre-
sponds to the chiller's nameplate voltage, current, and frequency.
Refer to machine nameplate in Fig. 12. The machine electrical
data nameplate is located on the right side of the control center.

PROVIDE MACHINE PROTECTION

Protect machine and VFD enclosure from construction dirt and
moisture. Keep protective shipping covers in place until machine
is ready for installation.
If machine is exposed to freezing temperatures after water circuits
have been installed, open waterbox drains and remove all water
from cooler and condenser. Leave drains open until system is
filled.
It is important to properly plan before installing a 23XRV unit to
ensure that the environment and operating conditions are satisfac-
tory. The installation must comply with all requirements in the cer-
tified prints.
Chiller should be installed in an indoor environment where the
ambient temperature is between 40 and 104°F (4 and 40°C) with
relative humidity of 95% or less.
INPUT
ENCLOSURE
VOLTAGE (V)
TYPE
RANGE
NEMA 1
380 to 460
NEMA 1
380 to 460
NEMA 1
380 to 460
NEMA 1
380 to 460
INPUT VOLTAGE
(Digit Y of part number)
Y
Voltage/Hz
3
380v / 60 Hz
4
416v / 60 Hz
5
460v / 60 Hz
7
575v / 60 Hz
9
400v / 50 Hz
11
MAX INPUT
MAX OUTPUT
CURRENT
CURRENT
(AMPS)
(AMPS)
440
440
520
440
520
520
608
608
a
MAX INPUT
MAX OUTPUT
CURRENT
CURRENT
(AMPS)
(AMPS)
230
269
335
445
a
at 4 kHz
at 2 kHz
b
230
269
335
445

Advertisement

Table of Contents
loading

Table of Contents