Functional Description
P
C
OWER
ONSUMPTION WITH
Tables 2 through 6 list the power consumed and dissipated by the ELU-319 List 5E and List 6E when it is used
with any of the four basic doubler types in the HiGain family. The maximum current drawn by the CO supply is
also listed.
Table 8
covers single doubler, line-powered circuits on 9 kft, 26 AWG (0.4 mm) loops.
Table 8. EDU-451 List 1 or List 2 Maximum Power Parameters (No Doubler)
ERU Model
ERU-412 List 1 and List 2
ERU-412 List 1E and List 2E
Table 9
applies to two doubler, line-powered circuits on 9 kft, 26 AWG (0.4 mm) loops.
Table 9. EDU-409 List 2 Maximum Power Parameters (Two Doublers)
ERU Model No.
ERU-412 List 1E
Table 10
applies to three doubler, line-powered circuits on 9 kft, 26 AWG (0.4 mm) loops.
Table 10. EDU-409 List 2 Maximum Power Parameters (Three Doublers)
ERU Model No.
ERU-412 List 1E,
3-doubler, line-powered
ERU-412 List 1E,
4-doubler, local power
14
D
OUBLERS
48 V Power
Heat Dissipation - W
Consumption - W
25.9
21
48 V Power
Heat Dissipation -W
Consumption - W
17.8
48 V Power
Heat Dissipation -W
Consumption - W
21
23.7
January 26, 2000
42.5 V Current - mA
7.2
610
6.3
494
42.5 V Current - mA
6.2
418
42.5 V Current - mA
6.6
495
7.4
557
ELU-319 List 5E and List 6E
150-319-205-05, Issue 5